AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230 TXV 36,200 16.20 12.00 CX34-49 SLP98UH090V36C 4020686
XC16-036-230 TXV 36,600 16.50 12.00 CX34-49 SLP98UH090V48C 4020687
XC16-036-230 TXV 36,600 16.50 12.00 CX34-49 SLP98UH090V60C 4020688
XC16-036-230 TXV 36,600 16.50 12.20 CX34-49 SLP98UH110V60C 4020689
XC16-036-230 TXV 35,600 14.50 11.00 CX34-49 3068637
XC16-048-230 TXV 45,500 14.70 11.50 C33-44C G61MPV-60C-090 1003983
XC16-048-230 TXV 45,500 14.70 11.20 C33-44C G61MPV-60C-091 1046650
XC16-048-230 TXV 45,500 14.50 11.50 C33-44C G61MPV-60C-110 1003988
XC16-048-230 TXV 45,500 14.50 11.50 C33-44C G61MPV-60C-111 1046651
XC16-048-230 TXV 45,500 14.70 11.20 C33-48 G61MPV-60C-091 1046652
XC16-048-230 TXV 45,500 14.50 11.50 C33-48 G61MPV-60C-110 1003986
XC16-048-230 TXV 45,500 14.50 11.50 C33-48 G61MPV-60C-111 1046653
XC16-048-230 TXV 45,000 14.20 11.20 C33-48 O23V5-140/154 1038249
XC16-048-230 TXV 46,000 15.00 11.70 C33-48 SL280UH090V60C 3933036
XC16-048-230 TXV 46,000 15.00 11.70 C33-48 SL280UH090XV60C 4235458
XC16-048-230 TXV 45,500 14.70 11.70 C33-48 SL280UH110V60C 3933037
XC16-048-230 TXV 45,500 14.70 11.70 C33-48 SL280UH110XV60C 4040519
XC16-048-230 TXV 45,500 13.70 11.20 C33-48 1003999
XC16-048-230 TXV 47,500 15.20 12.00 C33-49 G61MPV-60C-090 1003774
XC16-048-230 TXV 47,500 15.00 11.70 C33-49 G61MPV-60C-091 1046654
XC16-048-230 TXV 47,500 15.00 12.00 C33-49 G61MPV-60C-110 1003775
XC16-048-230 TXV 47,000 15.00 11.70 C33-49 G61MPV-60C-111 1046655
XC16-048-230 TXV 46,500 14.70 11.70 C33-49 O23V5-140/154 1038250
XC16-048-230 TXV 47,500 15.70 12.20 C33-49 SL280UH090V60C 3933038
XC16-048-230 TXV 47,500 15.70 12.20 C33-49 SL280UH090XV60C 4235459
XC16-048-230 TXV 47,500 15.50 12.20 C33-49 SL280UH110V60C 3933039
XC16-048-230 TXV 47,500 15.50 12.20 C33-49 SL280UH110XV60C 4040520
XC16-048-230 TXV 47,000 14.20 11.70 C33-49 1003730
XC16-048-230 TXV 46,000 15.20 11.20 C33-50/60C CBWMV-60C-100 1088641
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C G61MPV-60C-090 1003766
XC16-048-230 TXV 46,000 14.70 11.50 C33-50/60C G61MPV-60C-091 1046656
XC16-048-230 TXV 46,000 14.70 11.70 C33-50/60C G61MPV-60C-110 1003768
XC16-048-230 TXV 46,000 14.70 11.70 C33-50/60C G61MPV-60C-111 1046657
XC16-048-230 TXV 46,000 14.50 11.20 C33-50/60C O23V5-140/154 1038251
XC16-048-230 TXV 46,500 15.20 11.70 C33-50/60C SL280UH090V60C 3933040
XC16-048-230 TXV 46,500 15.20 11.70 C33-50/60C SL280UH090XV60C 4235460
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C SL280UH110V60C 3933041
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C SL280UH110XV60C 4040521
XC16-048-230 TXV 46,500 13.70 11.20 C33-50/60C 1003726
XC16-048-230 TXV 47,000 15.50 12.20 C33-60D G61MPV-60D-135 3133211
XC16-048-230 TXV 46,500 15.00 11.50 C33-60D O23V5-140/154 1003981
XC16-048-230 TXV 47,000 15.50 12.20 C33-60D SL280UH135V60D 3933042
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.