XC16 - 2 to 5 Ton Air Conditioner / Page 19
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-048-230 TXV 46,500 14.00 11.50 C33-60D 1004000
XC16-048-230 TXV 48,000 15.70 12.20 C33-62C G61MPV-60C-090 1003978
XC16-048-230 TXV 48,000 15.50 12.00 C33-62C G61MPV-60C-091 1046658
XC16-048-230 TXV 48,000 15.50 12.30 C33-62C G61MPV-60C-111 1046659
XC16-048-230 TXV 47,500 15.20 12.00 C33-62C O23V5-140/154 1003977
XC16-048-230 TXV 48,000 16.00 12.20 C33-62C SL280UH090V60C 3933043
XC16-048-230 TXV 48,000 16.00 12.20 C33-62C SL280UH090XV60C 4235461
XC16-048-230 TXV 48,000 15.70 12.50 C33-62C SL280UH110V60C 3933044
XC16-048-230 TXV 48,000 15.70 12.50 C33-62C SL280UH110XV60C 4040522
XC16-048-230 TXV 47,500 14.20 11.70 C33-62C 1003996
XC16-048-230 TXV 47,000 15.20 12.00 C33-62D O23V5-140/154 1003975
XC16-048-230 TXV 47,500 15.50 12.20 C33-62D SL280UH135V60D 3933045
XC16-048-230 TXV 47,000 14.20 11.50 C33-62D 1003997
XC16-048-230 TXV 48,000 14.70 11.70 CB26UH-042 1003995
XC16-048-230 TXV 48,000 14.70 12.00 CB26UH-048 1003952
XC16-048-230 TXV 48,000 14.70 11.70 CBX26UH-042 1003953
XC16-048-230 TXV 48,000 14.70 12.00 CBX26UH-048 1003954
XC16-048-230 TXV 47,000 15.70 12.20 CBX27UH-048 1145118
XC16-048-230 TXV 46,500 15.50 12.20 CBX27UH-060 1145119
XC16-048-230 TXV 47,000 14.70 12.00 CBX32M-048 1003958
XC16-048-230 TXV 47,500 14.50 11.70 CBX32M-060 1003957
XC16-048-230 TXV 47,000 15.70 12.20 CBX32MV-048 1003956
XC16-048-230 TXV 47,500 15.70 12.20 CBX32MV-060 1003955
XC16-048-230 TXV 47,500 15.70 12.50 CBX32MV-068 1003963
XC16-048-230 TXV 47,000 15.70 12.20 CBX40UHV-048 3291798
XC16-048-230 TXV 47,500 15.70 12.20 CBX40UHV-060 3291847
XC16-048-230 TXV 45,000 15.00 11.70 CH23-51 SL280UH090V60C 3933046
XC16-048-230 TXV 45,000 15.00 11.70 CH23-51 SL280UH090XV60C 4235462
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH110V60C 3933047
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH110XV60C 4040523
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH135V60D 3933048
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH090V48C 4020710
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH090V60C 4020711
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH110V60C 4020712
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH135V60D 4020713
XC16-048-230 TXV 45,000 13.50 11.20 CH23-51 1003722
XC16-048-230 TXV 46,000 15.50 12.00 CH23-65 SL280UH090V60C 3933049
XC16-048-230 TXV 46,000 15.50 12.00 CH23-65 SL280UH090XV60C 4235463
XC16-048-230 TXV 45,500 15.20 12.00 CH23-65 SL280UH110V60C 3933050
XC16-048-230 TXV 45,500 15.20 12.00 CH23-65 SL280UH110XV60C 4040518
XC16-048-230 TXV 46,000 15.20 12.00 CH23-65 SL280UH135V60D 3933051
XC16-048-230 TXV 45,500 15.20 11.70 CH23-65 SLP98UH090V48C 4020714
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.