XC16 - 2 to 5 Ton Air Conditioner / Page 21
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-048-230 TXV 47,000 15.20 12.00 CH33-50/60C SL280UH110XV60C 4040526
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH090V48C 4020725
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH090V60C 4020726
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH110V60C 4020727
XC16-048-230 TXV 47,000 14.20 11.70 CH33-50/60C 1050279
XC16-048-230 TXV 47,000 15.50 12.20 CH33-60D G61MPV-60D-135 1003993
XC16-048-230 TXV 47,000 15.50 12.20 CH33-60D SL280UH135V60D 3933059
XC16-048-230 TXV 47,000 15.20 12.00 CH33-60D SLP98UH135V60D 4020728
XC16-048-230 TXV 46,500 14.00 11.50 CH33-60D 1003992
XC16-048-230 TXV 47,500 15.50 12.20 CH33-62D G61MPV-60D-135 1003758
XC16-048-230 TXV 47,000 15.50 12.20 CH33-62D SL280UH135V60D 3933060
XC16-048-230 TXV 47,000 15.20 12.00 CH33-62D SLP98UH135V60D 4020729
XC16-048-230 TXV 47,000 14.00 11.50 CH33-62D 1003725
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-091 1046664
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-110 1003754
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-111 1046665
XC16-048-230 TXV 44,500 14.50 11.50 CR33-48 SL280DF090V60C 3933061
XC16-048-230 TXV 44,500 14.70 11.50 CR33-48 SL280DF110V60C 3933062
XC16-048-230 TXV 45,000 14.70 11.70 CR33-48 SLP98DF090V48C 4020730
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 SLP98DF090V60C 4020731
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 SLP98DF110V60C 4020732
XC16-048-230 TXV 44,500 13.20 11.00 CR33-48 1003771
XC16-048-230 TXV 46,000 15.20 11.70 CR33-50/60 G61MPV-60C-090 1003762
XC16-048-230 TXV 46,000 14.70 11.50 CR33-50/60 G61MPV-60C-091 1046666
XC16-048-230 TXV 46,000 15.00 11.70 CR33-50/60 G61MPV-60C-111 1046667
XC16-048-230 TXV 46,500 15.20 12.00 CR33-50/60 SL280DF090V60C 3933063
XC16-048-230 TXV 46,500 15.20 12.20 CR33-50/60 SL280DF110V60C 3933064
XC16-048-230 TXV 46,000 15.00 11.50 CR33-50/60 SLP98DF090V48C 4020733
XC16-048-230 TXV 46,000 15.20 11.70 CR33-50/60 SLP98DF090V60C 4020734
XC16-048-230 TXV 46,500 15.20 11.70 CR33-50/60 SLP98DF110V60C 4020735
XC16-048-230 TXV 46,000 13.70 11.20 CR33-50/60 1003770
XC16-048-230 TXV 46,000 13.70 11.20 CR33-60 1005092
XC16-048-230 TXV 46,000 15.00 11.70 CX34-43 SL280UH090V48B 4016692
XC16-048-230 TXV 46,000 15.00 11.70 CX34-43 SL280UH090XV48B 4038706
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 CBWMV-60C-100 3060548
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 G61MPV-60C-090 1003961
XC16-048-230 TXV 45,500 14.70 11.20 CX34-44/48 G61MPV-60C-091 1046668
XC16-048-230 TXV 45,500 14.50 11.50 CX34-44/48 G61MPV-60C-111 1046669
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SL280UH090V48B 4016693
XC16-048-230 TXV 46,000 15.00 11.70 CX34-44/48 SL280UH090V60C 3933065
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SL280UH090XV48B 4038711
XC16-048-230 TXV 46,000 15.00 11.70 CX34-44/48 SL280UH090XV60C 4235467
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.