AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110V60C 3933066
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110XV60C 4040527
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V48C 4020736
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V60C 4020737
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH110V60C 4020738
XC16-048-230 TXV 45,500 13.70 11.20 CX34-44/48 3024355
XC16-048-230 TXV 47,500 15.20 12.00 CX34-49 G61MPV-60C-090 3490811
XC16-048-230 TXV 47,500 15.00 11.70 CX34-49 G61MPV-60C-091 1046670
XC16-048-230 TXV 47,500 15.00 12.00 CX34-49 G61MPV-60C-110 1003910
XC16-048-230 TXV 47,000 15.00 11.70 CX34-49 G61MPV-60C-111 1046671
XC16-048-230 TXV 46,500 14.70 11.70 CX34-49 O23V5-140/154 1003909
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090V60C 3933067
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090XV60C 4235468
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110V60C 3933068
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110XV60C 4040528
XC16-048-230 TXV 47,000 15.50 12.00 CX34-49 SLP98UH090V48C 4020739
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SLP98UH090V60C 4020740
XC16-048-230 TXV 47,500 15.50 12.00 CX34-49 SLP98UH110V60C 4020741
XC16-048-230 TXV 47,000 14.20 11.70 CX34-49 1050269
XC16-048-230 TXV 46,000 15.20 11.20 CX34-50/60C CBWMV-60C-100 1088640
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C G61MPV-60C-090 1003788
XC16-048-230 TXV 46,000 14.70 11.50 CX34-50/60C G61MPV-60C-091 1046672
XC16-048-230 TXV 46,000 14.70 11.70 CX34-50/60C G61MPV-60C-111 1046673
XC16-048-230 TXV 46,000 14.50 11.20 CX34-50/60C O23V5-140/154 1003785
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090V60C 3933069
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090XV60C 4235469
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110V60C 3933070
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110XV60C 4040529
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V48C 4020742
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V60C 4020743
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH110V60C 4020744
XC16-048-230 TXV 46,500 13.70 11.20 CX34-50/60C 1050270
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D G61MPV-60D-135 1003906
XC16-048-230 TXV 46,500 15.00 11.50 CX34-60D O23V5-140/154 1003905
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D SL280UH135V60D 3933071
XC16-048-230 TXV 47,000 15.20 12.00 CX34-60D SLP98UH135V60D 4020745
XC16-048-230 TXV 46,500 14.00 11.50 CX34-60D 1050271
XC16-048-230 TXV 48,000 15.50 12.00 CX34-62C G61MPV-60C-091 1046674
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-110 1003904
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-111 1046675
XC16-048-230 TXV 47,500 15.20 12.00 CX34-62C O23V5-140/154 1003903
XC16-048-230 TXV 48,000 16.00 12.20 CX34-62C SL280UH090V60C 3933072
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.