AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110V60C 3933066
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110XV60C 4040527
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V48C 4020736
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V60C 4020737
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH110V60C 4020738
XC16-048-230 TXV 45,500 13.70 11.20 CX34-44/48 3024355
XC16-048-230 TXV 47,500 15.20 12.00 CX34-49 G61MPV-60C-090 3490811
XC16-048-230 TXV 47,500 15.00 11.70 CX34-49 G61MPV-60C-091 1046670
XC16-048-230 TXV 47,500 15.00 12.00 CX34-49 G61MPV-60C-110 1003910
XC16-048-230 TXV 47,000 15.00 11.70 CX34-49 G61MPV-60C-111 1046671
XC16-048-230 TXV 46,500 14.70 11.70 CX34-49 O23V5-140/154 1003909
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090V60C 3933067
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090XV60C 4235468
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110V60C 3933068
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110XV60C 4040528
XC16-048-230 TXV 47,000 15.50 12.00 CX34-49 SLP98UH090V48C 4020739
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SLP98UH090V60C 4020740
XC16-048-230 TXV 47,500 15.50 12.00 CX34-49 SLP98UH110V60C 4020741
XC16-048-230 TXV 47,000 14.20 11.70 CX34-49 1050269
XC16-048-230 TXV 46,000 15.20 11.20 CX34-50/60C CBWMV-60C-100 1088640
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C G61MPV-60C-090 1003788
XC16-048-230 TXV 46,000 14.70 11.50 CX34-50/60C G61MPV-60C-091 1046672
XC16-048-230 TXV 46,000 14.70 11.70 CX34-50/60C G61MPV-60C-111 1046673
XC16-048-230 TXV 46,000 14.50 11.20 CX34-50/60C O23V5-140/154 1003785
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090V60C 3933069
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090XV60C 4235469
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110V60C 3933070
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110XV60C 4040529
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V48C 4020742
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V60C 4020743
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH110V60C 4020744
XC16-048-230 TXV 46,500 13.70 11.20 CX34-50/60C 1050270
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D G61MPV-60D-135 1003906
XC16-048-230 TXV 46,500 15.00 11.50 CX34-60D O23V5-140/154 1003905
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D SL280UH135V60D 3933071
XC16-048-230 TXV 47,000 15.20 12.00 CX34-60D SLP98UH135V60D 4020745
XC16-048-230 TXV 46,500 14.00 11.50 CX34-60D 1050271
XC16-048-230 TXV 48,000 15.50 12.00 CX34-62C G61MPV-60C-091 1046674
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-110 1003904
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-111 1046675
XC16-048-230 TXV 47,500 15.20 12.00 CX34-62C O23V5-140/154 1003903
XC16-048-230 TXV 48,000 16.00 12.20 CX34-62C SL280UH090V60C 3933072
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.