XC16 - 2 to 5 Ton Air Conditioner / Page 24
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-060-230 TXV 60,000 15.70 11.70 C33-62C SL280UH090XV60C 4235473
XC16-060-230 TXV 59,500 15.50 11.50 C33-62C SL280UH110V60C 3933081
XC16-060-230 TXV 59,500 15.50 11.50 C33-62C SL280UH110XV60C 4040533
XC16-060-230 TXV 60,000 14.70 11.70 C33-62C 1003950
XC16-060-230 TXV 59,500 15.70 12.00 C33-62D G61MPV-60D-135 3281425
XC16-060-230 TXV 59,000 15.20 11.50 C33-62D O23V5-140/154 1003932
XC16-060-230 TXV 59,000 15.50 11.70 C33-62D SL280UH135V60D 3933082
XC16-060-230 TXV 59,000 14.50 11.50 C33-62D 1003965
XC16-060-230 TXV 60,000 15.20 11.70 CB26UH-060 1003943
XC16-060-230 TXV 60,000 15.20 11.70 CBX26UH-060 1003948
XC16-060-230 TXV 58,500 15.50 11.70 CBX27UH-060 1145120
XC16-060-230 TXV 59,000 14.70 11.70 CBX32M-060 1003949
XC16-060-230 TXV 58,500 15.70 11.70 CBX32MV-048 1003947
XC16-060-230 TXV 59,000 15.70 11.70 CBX32MV-060 1003946
XC16-060-230 TXV 59,000 15.70 12.00 CBX32MV-068 1003945
XC16-060-230 TXV 58,500 15.70 11.70 CBX40UHV-048 3291799
XC16-060-230 TXV 59,000 15.70 11.70 CBX40UHV-060 3291848
XC16-060-230 TXV 55,500 13.50 10.70 CH23-51 3986401
XC16-060-230 TXV 55,500 13.50 10.70 CH23-51 3986402
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SL280UH090V60C 3933083
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SL280UH090XV60C 4235474
XC16-060-230 TXV 56,500 14.70 11.00 CH23-65 SLP98UH090V60C 4020690
XC16-060-230 TXV 56,000 15.00 11.20 CH23-65 SLP98UH110V60C 4020691
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SLP98UH135V60D 4020692
XC16-060-230 TXV 56,500 14.00 11.20 CH23-65 1003966
XC16-060-230 TXV 59,500 15.50 11.70 CH23-68 SL280UH135V60D 3933084
XC16-060-230 TXV 59,000 15.70 11.70 CH23-68 SLP98UH135V60D 4020693
XC16-060-230 TXV 60,000 14.50 11.70 CH23-68 1003783
XC16-060-230 TXV 58,500 14.20 11.50 CH33-50/60C CBWMV-60C-120 1260281
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C G61MPV-60C-090 1003938
XC16-060-230 TXV 58,500 14.70 11.20 CH33-50/60C G61MPV-60C-091 1046682
XC16-060-230 TXV 58,500 15.00 11.50 CH33-50/60C G61MPV-60C-110 1003942
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C G61MPV-60C-111 1046683
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C SL280UH090V60C 3933085
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C SL280UH090XV60C 4235475
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SL280UH110V60C 3933086
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SL280UH110XV60C 4040534
XC16-060-230 TXV 58,000 15.00 11.00 CH33-50/60C SLP98UH090V60C 4020694
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SLP98UH110V60C 4020695
XC16-060-230 TXV 58,500 14.50 11.50 CH33-50/60C 1003967
XC16-060-230 TXV 58,500 15.20 11.70 CH33-60D CBWMV-60C-100 1086362
XC16-060-230 TXV 58,500 15.50 11.70 CH33-60D G61MPV-60D-135 3069477
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.