XC16 - 2 to 5 Ton Air Conditioner / Page 25
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-060-230 TXV 58,000 15.20 11.50 CH33-60D SL280UH135V60D 3933087
XC16-060-230 TXV 58,000 15.50 11.50 CH33-60D SLP98UH135V60D 4020696
XC16-060-230 TXV 58,000 14.20 11.50 CH33-60D 1003964
XC16-060-230 TXV 58,500 15.20 11.70 CH33-62D G61MPV-60C-090 1132864
XC16-060-230 TXV 58,000 15.00 11.50 CH33-62D G61MPV-60C-090 4184803
XC16-060-230 TXV 58,500 15.20 11.50 CH33-62D G61MPV-60C-091 1132865
XC16-060-230 TXV 58,500 15.00 11.70 CH33-62D G61MPV-60C-110 1132866
XC16-060-230 TXV 58,000 15.20 11.50 CH33-62D G61MPV-60C-110 4184805
XC16-060-230 TXV 58,500 15.20 11.70 CH33-62D G61MPV-60C-111 1132867
XC16-060-230 TXV 58,500 15.50 11.70 CH33-62D G61MPV-60D-135 1003806
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH090V60C 4184806
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH090XV60C 4235818
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH110V60C 4184807
XC16-060-230 TXV 58,500 15.20 11.50 CH33-62D SL280UH135V60D 3933088
XC16-060-230 TXV 58,500 15.50 11.70 CH33-62D SLP98UH135V60D 4020697
XC16-060-230 TXV 58,500 14.20 11.50 CH33-62D 1003782
XC16-060-230 TXV 57,500 15.20 11.50 CR33-60 G61MPV-60D-135 1003801
XC16-060-230 TXV 57,000 15.00 11.20 CR33-60 SLP98DF090V60C 4020706
XC16-060-230 TXV 57,000 14.70 11.20 CR33-60 SLP98DF110V60C 4020707
XC16-060-230 TXV 57,500 14.20 11.20 CR33-60 1003781
XC16-060-230 TXV 58,500 15.20 11.70 CX34-49 G61MPV-60C-090 1003919
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 G61MPV-60C-091 1046684
XC16-060-230 TXV 59,000 15.00 11.70 CX34-49 G61MPV-60C-110 3094650
XC16-060-230 TXV 59,000 15.20 11.70 CX34-49 G61MPV-60C-111 1046685
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 O23V5-140/154 1003916
XC16-060-230 TXV 58,500 15.20 11.50 CX34-49 SL280UH090V60C 3933089
XC16-060-230 TXV 58,500 15.20 11.50 CX34-49 SL280UH090XV60C 4235476
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 SL280UH110V60C 3933090
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 SL280UH110XV60C 4040535
XC16-060-230 TXV 58,500 15.20 11.20 CX34-49 SLP98UH090V60C 4020698
XC16-060-230 TXV 58,500 15.20 11.20 CX34-49 SLP98UH110V60C 4020699
XC16-060-230 TXV 59,000 14.50 11.50 CX34-49 1050274
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C CBWMV-60C-120 3184076
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-090 1003797
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-091 1046686
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-110 1003798
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-111 1046687
XC16-060-230 TXV 57,500 14.50 11.20 CX34-50/60C O23V5-140/154 1003796
XC16-060-230 TXV 57,500 15.00 11.20 CX34-50/60C SL280UH090V60C 3933091
XC16-060-230 TXV 57,500 15.00 11.20 CX34-50/60C SL280UH090XV60C 4235477
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SL280UH110V60C 3933092
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SL280UH110XV60C 4040536
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.