70
slP99uHV
Table 27. SLP99UHV
Starting at 70% of High Fire
(Temperaturerisebasedonprimarylimitandroomat70˚andbeforetrippingfurnaceprimarylimit)
Model SLP99UH070XV36B SLP99UH090XV36C SLP99UH090XV48C SLP99UH090XV60C
Primary Limit 145˚F 150˚F 140˚F 140˚F
Minimum CFM (Fail at CFM) Zoning
553CFM@75˚FTR
Output BTU 44,800
688@80˚FTR
Output BTU 59,500
787CFM@70˚FTR
Output BTU 59,500
805CFM@70˚FTR
Output BTU 60,900
Maximum CFM
1,185CFM@50˚FTR
Output BTU 64,000
1,312CFM@60˚FTR
Output BTU 85,000
1,574CFM@50˚FTR
Output BTU 85,000
1,611CFM@50˚FTR
Output BTU 87,000
Model SLP99UH110XV60C SLP99UH135XV60D
Primary Limit 140˚ 135˚
Minimum CFM (Fail at CFM) Zoning
981CFM@70˚FTR
Output BTU 74,200
1,276CFM@65˚FTR
Output BTU 89,600
Maximum CFM
1,963CFM@50˚FTR
Output BTU 106,000
2,020CFM@55˚FTR
Output BTU 128,000