Product Type | Heat Pump |
---|---|
Series | KGB |
Tonnage | 4 Ton |
Refrigerant Type | R-410A |
Voltage | 208/230V |
Phase | 1 |
Sound Level (Outdoor Unit) | 76 dB |
HSPF | 8.20 |
Cooling Capacity | 48000 BTU/h |
Heating Capacity | 48000 BTU/h |
Crucial safety warnings for installation, electrical hazards, and sharp edges.
Procedures to prevent damage to electronic components from static discharge.
Performance data for standard gas heat configurations across models.
Performance data for low NOx gas heat configurations across models.
Air volume (cfm) at various static pressures for downflow configurations.
Air volume (cfm) at various static pressures for horizontal configurations.
Air volume (cfm) at various static pressures for downflow PSC units.
Air volume (cfm) at various static pressures for horizontal PSC units.
Air volume (cfm) at various static pressures for 3-ton belt drive units.
Air volume (cfm) at various static pressures for 3-ton belt drive units.
Air volume (cfm) at various static pressures for 4-ton belt drive units.
Air volume (cfm) at various static pressures for 4-ton belt drive units.
Air volume (cfm) at various static pressures for 5-ton belt drive units.
Air volume (cfm) at various static pressures for 5-ton belt drive units.
Air volume (cfm) at various static pressures for 6-ton downflow belt drive units.
Air volume (cfm) at various static pressures for 6-ton horizontal belt drive units.
Air volume (cfm) at various static pressures for 7.5-ton downflow belt drive units.
Air volume (cfm) at various static pressures for 7.5-ton horizontal belt drive units.
Electrical specifications for 2-ton and 2.5-ton Direct Drive ECM units.
Electrical specifications for 3-ton, 4-ton, and 5-ton Direct Drive ECM units.
Electrical specifications for 3-ton Direct Drive PSC units across voltage ranges.
Electrical specifications for 4-ton Direct Drive PSC units across voltage ranges.
Electrical specifications for 5-ton Direct Drive PSC units across voltage ranges.
Description of gas relay and the primary burner control module.
Explanation of A3 functions, safety features, and warnings.
Description of the compressor and critical safety precautions.
Details on safety switches for temperature and pressure monitoring.
Wiring diagram for adjusting blower speed on 208/230V units.
Wiring diagram for adjusting blower speed on 460/575V units.
Methods for calculating CFM and adjusting belt drive blower speeds.
Information on gas valves (GV1), spark electrode, and related safety.
Critical safety warnings before placing the unit into operation.
Procedures for verifying refrigerant charge and critical safety warnings.
Instructions for safely shutting down the unit in emergencies.
Guidelines for testing gas piping for leaks and pressure.
Procedures for testing gas supply pressure and adjusting manifold pressure.