SPECIFICATIONS - WALL-MOUNTED INDOOR UNITS - 009-012
Model No. MWMA009S4-1L MWMA009S4-1P MWMA012S4-1L MWMA012S4-1P
Nominal Tons 0.75 0.75 1 1
Power Supply - 60 hz - 1 phase 115V 208/230V 115V 208/230V
Rated load amps 0.19 0.06 0.19 0.06
Output (W) 20 20 20 20
Air Volume - cfm (High/Medium/Low) 340/260/205 340/260/205 340/260/205 340/260/205
Sound Data (dBA) - Low/Medium/High 29/36.4/43.7 29.1/36.2/43.3 28.9/36.4/43.9 29.3/36.2/43
Piping Connections - Liquid/Gas - o.d. - are - in. 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2
Drain connection o.d. - in. 1111
Net/Shipping weights - lbs. 20 / 26 20 / 26 20 / 26 20 / 26
SPECIFICATIONS - WALL-MOUNTED INDOOR UNITS - 018-030
Model No. MWMA018S4-1P MWMA024S4-1P MWMA030S4-1P
Nominal Tons 1.5 2 2.5
Power Supply - 60 hz - 1 phase 208/230V 208/230V 208/230V
Rated load amps 0.13 0.3 0.3
Output (W) 58 60 60
Air Volume - cfm (High/Medium/Low) 595/460/355 750/690/565 750/690/565
Sound Data (dBA) - Low/Medium/High 30.5/38.6/46.6 39.4/44.7/50 39/44.9/50.7
Piping Connections - Liquid/Gas - o.d. - are - in. 1/4 / 1/2 3/8 / 5/8 3/8 / 5/8
Drain connection o.d. - in. 1 1 1
Total refrigerant pipe length - ft. 98 98 164
Net/Shipping weights - lbs. 27 / 35 40 / 51 40 / 51