Do you have a question about the Lennox ML193UH070P36B and is the answer not in the manual?
Provides an overview of the ML193UH series furnaces, their capabilities, and features.
Highlights critical safety precautions, including electrical shock and sharp edges.
Details required clearances for installation around the unit.
Identifies major components of the ML193UH furnace via a diagram.
Details the transformer, door interlock switch, and ignition control within the control box.
Explains the integrated control, ignitor, and flame sensor functionality.
Describes how to adjust the fan off delay settings for comfort.
Lists and explains the terminal designations on the integrated control board.
Provides terminal designations for 4-pin and 12-pin connectors.
Lists diagnostic codes and their corresponding LED status for troubleshooting.
Explains how to adjust heating fan on/off times and cooling fan settings.
Details the process and requirements for twinning two furnaces.
Identifies and describes the ignitor, flame sensor, and rollout switches.
Describes the function and characteristics of the primary limit, heat exchanger, and burners.
Explains the operation and replacement of the gas valve.
Details the combustion air inducer, its housing, and associated components.
Explains the function and operation of the combustion air pressure switch.
Guides on how to measure pressure differential for system checks.
Describes the blower motor and capacitor within the blower compartment.
Lists approved piping and fitting materials and specifications for venting.
Details outdoor termination options based on input size and vent style.
Provides step-by-step instructions for cementing pipe joints.
Covers pipe suspension, wall thickness, and general venting considerations.
Shows equipment setup for confined spaces (attic/crawlspace).
Explains vent pipe options and installation rules.
A step-by-step guide to sizing vent pipe diameter based on various factors.
Illustrates typical exhaust pipe connections for upflow direct or non-direct vent.
Shows typical exhaust pipe connections for horizontal direct or non-direct vent.
Illustrates typical air intake pipe connections for upflow direct vent applications.
Shows typical air intake pipe connections for horizontal direct vent applications.
Instructions for routing intake piping in direct vent applications.
Guidelines for intake piping in non-direct vent applications.
Covers general rules for vent terminations, including location and clearances.
Table specifying exhaust pipe size reductions for different models.
Instructions and diagrams for field-fabricated wall vent terminations.
Shows alternative termination methods using tees and elbows.
Explains the routing and installation of condensate piping.
Covers initial checks before starting the furnace, including wiring and gas.
Lists common issues and checks when the unit fails to operate.
Details gas piping requirements, leak testing, and pressure checks.
Covers manifold pressure measurement and proper combustion checks.
Explains how to measure the flame signal using a transducer.
Covers blower operation, adjustment, and temperature rise measurement.
Details the procedure for measuring external static pressure.
Guidelines for inspecting and replacing air filters for optimal performance.
Instructions for preparing the unit for winter and maintaining condensate traps.
Steps for cleaning condensate hose screens to prevent blockages.
Provides a wiring diagram for units with integrated control 100973.
Explains the step-by-step process for furnace heating operation.