51
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
IndoorUnitA
1/4”liq+1/2”gas
IndoorUnitB
1/4”liq+1/2”gas
IndoorUnitC
1/4”liq+3/8”gas
IndoorUnitD
1/4”liq+3/8”gas
2
009(B)
1
1/4in.x3/8in.
018 (A) 1/4in.x1/2in.
2
009(B)
1
1/4in.x3/8in.
024(A)
2, 3
3/8 in. x 5/8 in.
2
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
2
012(B) 1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
2
012(B) 1/4in.x1/2in.
024(A)
2, 3
3/8 in. x 5/8 in.
2
018(B) 1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
2
018(B) 1/4in.x1/2in.
024(A)
2, 3
3/8 in. x 5/8 in.
2
024(B)
2, 3
3/8 in. x 5/8 in.
024(A)
2, 3
3/8 in. x 5/8 in.
3
009 (A)
1
1/4in.x3/8in.
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
3
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
012 (A) 1/4in.x1/2in.
3
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
018 (A) 1/4in.x1/2in.
3
009 (C) 1/4in.x3/8in.
009(B) 11/4in.x1/2in.
024(A)
2, 3
3/8 in. x 5/8 in.
3
009 (C) 1/4in.x3/8in.
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
3
009 (C) 1/4in.x3/8in.
012(B) 1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
3
009 (C) 1/4in.x3/8in.
024(A)
2, 3
3/8 in. x 5/8 in.
012(B) 1/4in.x1/2in.
3
009 (C) 1/4in.x3/8in.
018 (A) 1/4in.x1/2in.
018(B) 1/4in.x1/2in.
3
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
012 (C)
1
1/4in.x1/2in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnishedwithoutdoorunit).
2
1/4x3/8in.liquidpipeadaptorisrequiredforlinesetconnectiontothe048
outdoorunit(furnishedwithoutdoorunit).
3
1/2x5/8in.gaspipeadaptorisrequiredforlinesetconnectiontothe048outdoor
unit(furnishedwithoutdoorunit).
4
NotavalidcombinationwhenusingtheMPA036S4M.
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
IndoorUnitA
1/4”liq+1/2”gas
IndoorUnitB
1/4”liq+1/2”gas
IndoorUnitC
1/4”liq+3/8”gas
IndoorUnitD
1/4”liq+3/8”gas
3
012(B) 1/4in.x1/2in.
012 (C)
1
1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
3
012(B) 1/4in.x1/2in.
012 (C)
1
1/4in.x1/2in.
024(A)
2, 3
3/8 in. x 5/8 in.
3
012 (C)
1
1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
018(B) 1/4in.x1/2in.
4
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
009(D) 1/4in.x3/8in.
009 (A)
1
1/4in.x3/8in.
4
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
009(D) 1/4in.x3/8in.
012 (A) 1/4in.x1/2in.
4
009(B)
1
1/4in.x3/8in.
009 (C) 1/4in.x3/8in.
009(D) 1/4in.x3/8in.
018 (A) 1/4in.x1/2in.
4
009 (C) 1/4in.x3/8in.
009(D) 1/4in.x3/8in.
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
4
009 (C) 1/4in.x3/8in.
009(D) 1/4in.x3/8in.
012(B) 1/4in.x1/2in.
018 (A) 1/4in.x1/2in.
4
009(D) 1/4in.x3/8in.
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
012 (C)
1
1/4in.x1/2in.
4
012 (A) 1/4in.x1/2in.
012(B) 1/4in.x1/2in.
012 (C)
1
1/4in.x1/2in.
012(D)
1
1/4in.x1/2in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnishedwithoutdoorunit).
2
1/4x3/8in.liquidpipeadaptorisrequiredforlinesetconnectiontothe048
outdoorunit(furnishedwithoutdoorunit).
3
1/2x5/8in.gaspipeadaptorisrequiredforlinesetconnectiontothe048outdoor
unit(furnishedwithoutdoorunit).
4
NotavalidcombinationwhenusingtheMPA036S4M.