EasyManuals Logo

Lennox ROOFTOP FLEXY FCK 100 User Manual

Lennox ROOFTOP FLEXY FCK 100
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
IOM / ROOF-TOP FLEXY Series - Page 3
TRANSPORT - HANDLING
DELIVERY CHECKS
The equipment is shipped at the customers risk, and whose
responsiblity it is to ensure that the products are in good
working order on receipt by checking the following :
- The exterior has not been damaged in any way.
- The lifting and handling equipment are suitable for the
equipment and comply with the specifications of the
handling instructions enclosed herein.
- Accessories ordered for on site installation have been
delivered and are in good working order.
- The equipment supplied corresponds with the order and
matches the delivery note.
If the product is damaged, exact details must be confirmed in
writing by registered post to the shipping company within 48
hours of delivery (working days). A copy of the letter must be
addressed to Lennox and the supplier or distributor for
information purposes. Failure to comply will invalidate any
claim against the shipping company.
RATING PLATE
The rating plate provides a complete reference for the model
and ensures that the unit corresponds to the model ordered.
It states the electrical power consumption of the unit on start-
up, its rated power and its supply voltage. The supply voltage
must not deviate beyond +10/-15 %.
The start-up power is the maximum value likely to be achieved
for the specified operational voltage. The customer must have
a suitable electrical supply. It is therefore important to check
whether the supply voltage stated on the unit's rating plate is
compatible with that of the mains electrical supply.
The rating plate also states the year of manufacture as well
as the type of refrigerant used with the required volume
capacity of each compressor circuit.
STORAGE
When units are delivered on site they are not always required
immediately and are sometimes put into storage. In the event
of medium to long-term storage, we recommend the following
procedures :
- Ensure that there is no water in the hydraulic systems.
- Keep the heat exchanger covers in position (AKILUX
cover).
- Keep protective plastic film in position.
- Ensure the electrical panels are closed.
- Keep all items and options supplied in a dry and clean
place for future assembly before using the equipment.
MAINTENANCE KEY
On delivery we recommend that you keep the key which is
attached to an eyebolt in a safe and accesible place. This
allows you to open the panels for maintenance and installation
work.
The locks are ¼ turn + then tighter (figure 2).
Figure 2
Figure 1
N˚ SERIE
SERIAL NUMBER
TYPE
UNIT TYPE
Usine Dijon
Z.I. LONGVIC
21600 LONGVIC
FRANCE
ANNEE
YEAR
ALIMENTATION
ELEC. SUPPLY
A. MAXI
MAX. AMP.
REFRIGERANT
FLUIDE
Kg/CIRC
C1 C3C2 C4
I. DEMARR.
START UP AMP.
C. COMMANDE.
CONTROL CIR.
V
V
A
Hz
FCK 190
2000
215 900-01/01
400 3 50
140 269
24
111111 11
R407C

Questions and Answers: