Page 9
BLOWER DATA
SLP98UH090V60C BLOWER PERFORMANCE (less lter)
RIGHT SIDE RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 609 684 835 986 1136 1287 1437 1588
Increase (+7.5%) Heat CFM 551 623 769 914 1059 1205 1350 1496
Default Heat CFM 492 562 702 842 983 1123 1263 1403
Decrease (-7.5% ) Heat CFM 436 502 633 765 896 1028 1159 1291
Decrease (-15% ) Heat CFM 380 441 564 687 810 932 1055 1178
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 1040 1225 1380 1550 1555 1715 1920 2135
Default Cool CFM 960 1085 1225 1415 1430 1565 1790 1980
Decrease (-10%) Cool CFM 840 990 1085 1250 1280 1450 1580 1790
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
icomfort Touch™ Communicating Thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- 35%, 60%, 80%, 100% (four-stage) with time delays in-between
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 450 cfm.
SLP98UH090V60C BLOWER PERFORMANCE (less lter)
RIGHT SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 611 686 837 987 1138 1288 1439 1589
Increase (+7.5%) Heat CFM 554 626 771 916 1060 1205 1349 1494
Default Heat CFM 497 566 705 844 983 1121 1260 1399
Decrease (-7.5% ) Heat CFM 436 502 633 764 895 1026 1157 1288
Decrease (-15% ) Heat CFM 375 437 560 683 806 930 1053 1176
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 1035 1230 1390 1565 1560 1740 1940 2145
Default Cool CFM 950 1085 1235 1405 1410 1585 1785 1975
Decrease (-10%) Cool CFM 855 995 1085 1235 1260 1430 1595 1785