BLOWER DATA
SLP98UH070XV36B BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 484 531 625 718 812 906 999 1093
Increase (+7.5%) Heat CFM 446 490 579 667 756 845 933 1022
Default Heat CFM 407 449 533 616 700 784 867 951
Decrease (-7.5% ) Heat CFM 377 413 487 561 635 709 783 857
Decrease (-15% ) Heat CFM 346 378 442 506 571 635 699 763
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 590 705 805 955 840 1050 1205 1355
Default Cool CFM 540 640 725 820 750 945 1130 1230
Decrease (-10%) Cool CFM 500 580 665 720 685 805 990 1110
SLP98UH070XV36B BLOWER MOTOR WATTS - COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Increase (+10%) Cool CFM
Low 17 29 48 61 73 94 100 123 130 63 84 104 117 142 160 174 208 215 245 255
Medium-Low 30 50 66 79 107 128 137 159 178 121 137 165 195 213 239 257 283 303 329 342
Medium-High 51 70 92 106 127 150 170 184 207 195 214 243 268 290 324 348 370 387 409 434
High 88 109 134 150 184 201 221 243 265 290 309 344 372 399 421 445 474 495 520 532
Default Cool CFM
Low 12 25 38 52 66 83 96 105 117 43 65 75 98 120 139 152 170 192 212 228
Medium-Low 22 41 55 70 86 103 123 141 154 88 106 130 150 173 197 220 239 259 276 297
Medium-High 36 55 75 90 107 129 152 167 184 142 161 187 211 239 263 287 307 332 352 369
High 57 76 99 116 135 153 176 197 213 220 236 267 294 323 342 364 382 411 436 455
Decrease (-10%) Cool CFM
Low 8 22 32 50 60 77 86 100 116 31 48 63 83 102 122 137 150 166 188 203
Medium-Low 19 32 47 63 77 93 103 120 133 53 75 91 111 129 152 169 188 210 227 251
Medium-High 25 42 58 74 90 109 131 143 154 101 120 141 170 190 215 233 256 274 298 317
High 37 56 76 95 115 135 153 173 192 157 177 201 224 254 277 303 321 346 362 385
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 250 cfm.