SLP98UHV / Page 22
BLOWER DATA
SLP98UH070XV36B BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 471 519 614 709 805 900 996 1091
Increase (+7.5%) Heat CFM 435 480 570 660 751 841 931 1021
Default Heat CFM 399 441 526 611 696 781 866 951
Decrease (-7.5% ) Heat CFM 369 408 486 564 643 721 799 877
Decrease (-15% ) Heat CFM 339 375 446 517 589 660 732 803
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 595 715 815 950 855 1045 1205 1350
Default Cool CFM 520 655 755 840 790 945 1090 1255
Decrease (-10%) Cool CFM 490 595 670 745 720 845 985 1130
SLP98UH070XV36B BLOWER MOTOR WATTS - COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Increase (+10%) Cool CFM
Low 18 32 46 61 76 89 104 115 133 64 83 95 120 141 159 175 203 208 234 246
Medium-Low 34 52 69 86 104 126 141 160 174 109 131 150 179 204 219 239 268 283 313 335
Medium-High 63 82 98 115 138 153 173 187 209 177 197 227 246 273 311 328 354 383 402 408
High 88 107 131 148 175 192 217 235 253 255 281 312 346 382 402 430 465 489 506 533
Default Cool CFM
Low 12 25 37 55 66 82 94 105 121 43 61 76 99 121 133 162 169 189 211 224
Medium-Low 25 40 55 74 89 109 120 136 150 76 96 112 138 162 186 207 232 243 262 281
Medium-High 41 61 75 98 115 135 151 173 189 129 150 177 198 227 247 272 301 324 332 369
High 63 86 99 122 139 159 180 204 216 209 227 254 282 298 324 341 364 395 413 428
Decrease (-10%) Cool CFM
Low 9 20 35 48 59 75 86 94 110 29 43 63 84 99 113 131 144 164 185 197
Medium-Low 16 32 45 62 75 90 103 119 138 56 71 101 112 131 158 168 184 207 235 245
Medium-High 28 43 63 77 98 115 132 145 162 88 107 129 154 183 204 214 245 263 281 308
High 46 61 86 100 121 136 153 172 193 142 163 187 216 236 261 279 301 325 356 375
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 250 cfm.