BLOWER DATA
SLP98UH090XV36C BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 677 721 810 899 988 1076 1165 1254
Increase (+7.5%) Heat CFM 639 679 760 842 923 1004 1085 1167
Default Heat CFM 600 637 711 784 858 932 1005 1079
Decrease (-7.5% ) Heat CFM 573 606 673 740 806 873 939 1006
Decrease (-15% ) Heat CFM 546 576 635 695 754 814 873 933
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 605 715 810 930 850 995 1165 1305
Default Cool CFM 570 660 735 820 775 905 1050 1205
Decrease (-10%) Cool CFM 530 600 670 725 710 800 945 1070
SLP98UH090XV36C BLOWER MOTOR WATTS - COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Increase (+10%) Cool CFM
Low 12 29 43 59 75 92 111 123 139 41 62 86 102 123 145 165 185 205 229 253
Medium-Low 24 42 61 76 97 112 132 150 169 79 108 126 148 174 190 218 248 273 294 316
Medium-High 38 56 81 99 115 138 157 176 199 131 152 184 208 237 264 289 320 339 361 390
High 61 85 104 127 144 171 192 212 239 205 226 258 283 312 344 365 393 410 437 466
Default Cool CFM
Low 9 26 37 54 67 83 97 112 130 30 50 72 87 108 127 149 167 184 209 226
Medium-Low 19 37 53 67 83 101 119 135 153 62 86 101 129 144 165 189 215 232 251 275
Medium-High 27 48 65 82 101 119 139 161 177 91 114 140 163 195 220 239 265 289 315 339
High 42 62 85 99 121 143 162 183 203 149 167 201 228 258 289 316 333 355 389 403
Decrease (-10%) Cool CFM
Low 8 23 35 51 62 77 91 104 119 25 45 61 75 91 112 131 147 166 184 198
Medium-Low 13 29 46 60 78 93 110 125 140 40 61 81 103 119 143 162 179 204 220 245
Medium-High 22 41 57 70 88 109 127 144 159 70 92 120 133 165 178 203 231 246 274 301
High 29 50 69 83 106 123 143 164 183 101 124 151 180 203 227 257 276 306 326 358
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 250 cfm.