AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC14-042-230 TXV 42,500 15.50 13.00 CX34-62C SL280UH110XV60C 4040430
XC14-042-230 TXV 42,500 15.00 13.00 CX34-62C SLP98UH090V36C 4020524
XC14-042-230 TXV 42,500 15.20 13.00 CX34-62C SLP98UH090V48C 4020525
XC14-042-230 TXV 43,000 15.20 13.00 CX34-62C SLP98UH090V60C 4020526
XC14-042-230 TXV 42,500 15.20 13.00 CX34-62C SLP98UH110V60C 4020527
XC14-042-230 TXV 42,000 14.20 12.00 CX34-62C 1235285
XC14-042-230 TXV 42,500 15.50 13.20 CX34-62D SL280UH135V60D 3929205
XC14-042-230 TXV 41,500 14.00 12.00 CX34-62D 1348532
XC14-047-230 TXV 45,000 14.50 12.20 C33-48 G61MPV-60C-090 3869201
XC14-047-230 TXV 45,000 14.20 12.00 C33-48 G61MPV-60C-091 3869202
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 G61MPV-60C-110 3869203
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 G61MPV-60C-111 3869204
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090V60C 3869207
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090XV60C 4235244
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110V60C 3869208
XC14-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110XV60C 4040443
XC14-047-230 TXV 45,000 14.20 11.70 C33-48 3869209
XC14-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH090V60C 4253843
XC14-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH110V60C 4253844
XC14-047-230 TXV 47,000 15.20 12.70 C33-49 SLP98UH090V48C 4253845
XC14-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH090V60C 4253846
XC14-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH110V60C 4253847
XC14-047-230 TXV 48,000 16.00 13.00 C33-62C SL280UH090V60C 4253848
XC14-047-230 TXV 47,500 16.00 13.00 C33-62C SL280UH110V60C 4253849
XC14-047-230 TXV 47,000 14.70 12.50 C33-62C 3869210
XC14-047-230 TXV 46,500 16.00 13.00 CBX27UH-048 3869211
XC14-047-230 TXV 46,000 16.00 13.00 CBX32MV-060 3869212
XC14-047-230 TXV 46,000 16.00 13.00 CBX40UHV-060 3869213
XC14-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090V48B 4016682
XC14-047-230 TXV 46,500 15.20 12.70 CH33-43 SL280UH090V60C 4253850
XC14-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090XV48B 4038656
XC14-047-230 TXV 46,000 15.20 12.50 CH33-43 SL280UH110V60C 4253851
XC14-047-230 TXV 46,000 14.50 12.20 CH33-43C 4216090
XC14-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090V48B 4016683
XC14-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090XV48B 4038657
XC14-047-230 TXV 46,000 14.70 12.20 CH33-48 G61MPV-60C-090 3869215
XC14-047-230 TXV 46,000 14.70 12.20 CH33-48 G61MPV-60C-091 3869216
XC14-047-230 TXV 46,000 14.70 12.20 CH33-48 G61MPV-60C-110 3869217
XC14-047-230 TXV 46,000 14.70 12.50 CH33-48 G61MPV-60C-111 3869218
XC14-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090V60C 3869221
XC14-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090XV60C 4235245
XC14-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110V60C 3869222
XC14-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110XV60C 4040444
XC14-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH090V48C 4155391
XC14-047-230 TXV 46,000 14.70 12.20 CH33-48 SLP98UH090V60C 4155393
XC14-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH110V60C 4155395
XC14-047-230 TXV 45,500 14.50 12.00 CH33-48C 4216091
XC14-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090V48C 4253852
XC14-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090V60C 4253853
XC14-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH110V60C 4253854
XC14-047-230 TXV 46,500 14.50 12.20 CH33-50/60C 4253855
XC14-047-230 TXV 45,000 14.70 12.20 CR33-50/60 G61MPV-60C-090 3869225
XC14-047-230 TXV 44,500 14.50 12.00 CR33-50/60 G61MPV-60C-091 3869226
XC14-047-230 TXV 45,000 14.70 12.20 CR33-50/60 G61MPV-60C-110 3869227
XC14-047-230 TXV 45,000 14.70 12.20 CR33-50/60 G61MPV-60C-111 3869228
XC14-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF090V60C 3869231
XC14-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF110V60C 3869232
XC14-047-230 TXV 44,500 14.70 12.00 CR33-50/60 SLP98DF090V60C 4253863
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.