XP16
CHARGING INFORMATION FOR MODEL XP16−XXX−230−05
Unit Charging Sticker − 580275−01, dated 12/09
Table 2 − Indoor Units Matchups and Subcooling Charge Levels (XP16−XXX−230−05)
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add charge
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add charge
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add charge
Heat
+
5ºF
Cool
+
1ºF
Heat
+
5ºF
Cool
+
1ºF
Heat
+
5ºF
Cool
+
1ºF
XP16−024 CBX40UHV−042 24 11 3 0 CH33−60D 13 8 0 0
CBX26UH−024 45 6 0 15 CBX40UHV−048 24 11 3 0 CH33−62D 11 9 1 4
CBX27UH−024−2
30
20 7 0 9 CH33−43B 13 10 2 7 CR33−50/60C 15 7 0 10
CBX27UH−030−2
30
17 7 1 3 CH33−48C 37 11 2 11 CR33−60D 16 7 0 10
CBX32MV−024/0
30
20 7 0 9 CH33−43C 37 11 2 11 CX34−60D 14 8 1 0
CBX32MV−036 17 7 1 3 CR33−48B/C 49 7 0 9 CX34−62D 9 9 1 6
CBX40UHV−024 17 7 1 3 CX34−43B/C 29 9 2 11 CX34−62C 8 9 1 9
CBX40UHV−030 17 7 1 3 CX34−50/60C 29 9 2 11 XP16−060
CBX40UHV−036 17 7 1 3 XP16−048 CBX26UH−060 20 9 4 13
CH33−31B 31 8 1 12 CBX26UH−048 10 8 1 4
CBX27UH−060−2
30
10 6 2 3
CR33−30/36A/B/C 45 4 0 0 CBX27UH−048 19 9 1 4 CBX32M−060 17 6 1 12
CX34−31A/B 24 7 1 11 CBX27UH−060 13 14 3 3 CBX32MV−060 17 6 1 12
CX34−38A/B 18 8 1 10 CBX32M−048 19 9 1 4 CBX32MV−068 15 7 2 1
XP16−036 CBX32M−060 14 9 1 11 CBX40UHV−060 17 6 1 12
CBX26UH−036 50 5 0 0 CBX32MV−048 19 9 1 4 CH23−68 37 9 2 10
CBX27UH−036−2
30
22 7 0 9 CBX32MV−060 14 9 1 11 CH33−50/60C 33 8 1 0
CBX27UH−042−2
30
24 11 3 0 CBX32MV−068 9 8 1 11 CH33−62D 16 7 1 4
CBX32M−036 22 7 0 9 CBX40UHV−048 19 9 1 4 CR33−50/60C 24 7 0 0
CBX32MV−036 22 7 0 9 CBX40UHV−060 14 9 1 11 CR33−60D 24 7 0 0
CBX32MV−048 24 11 3 0 CH23−68 24 10 1 12 CX34−62C 21 9 2 16
CBX40UHV−030 22 7 0 9 CH33−49C 19 9 2 5 CX34−62D 13 7 1 4
CBX40UHV−036 22 7 0 9 CH33−50/60C 19 9 2 5
*Amount of charge required in additional to
charge shown on unit nameplate. (Remem-
ber to consider lin