Page 3
XP25
Electrical Data
208/230V-60 Hz-1 Ph
Model Number
Unit Compressor Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM RPM WATTS
Full
Load
Amps
(FLA)
MAX MIN MAX MIN MAX MIN
XP25-024-230-01 25 15.7 10.30 18.00 1/3 2580 1845 723 515 70 32 2.80
208/230V-60 Hz-1 Ph
Model Number
Unit Compressor Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM RPM WATTS
Full
Load
Amps
(FLA)
MAX MIN MAX MIN MAX MIN
XP25-036-230-01 25 20.3 14.00 18.00 1/3 4130 1865 850 390 214 40 2.80
208/230V-60 Hz-1 Ph
Model Number
Unit Compressor Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM RPM WATTS
Full
Load
Amps
(FLA)
MAX MIN MAX MIN MAX MIN
XP25-048-230-01 40 33.7 24.70 29.00 1/3 4040 3315 805 658 172 98 2.80
208/230V-60 Hz-1 Ph
Model Number
Unit Compressor Outdoor Fan (RPM varies with compressor RPM)
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
CFM RPM WATTS
Full
Load
Amps
(FLA)
MAX MIN MAX MIN MAX MIN
XP25-060-230-01 40 34.9 25.70 29.00 1/3 4240 3025 845 600 198 76 2.80
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.