Installing a ServeRAID SAS controller
To install the ServeRAID-8k-l SAS Controller or the ServeRAID-8k SAS Controller,
complete the following steps.
Note: The following illustration shows installing a ServeRAID-8k SAS controller; the
ServeRAID-8k-l SAS controller does not have a battery.
1 RAID controller 4 Battery mounting tabs
2 Battery cable 5 Battery mounting clips
3 Battery 6 Battery cable connector
1. Touch the static-protective package that contains the new ServeRAID SAS
controller to any unpainted metal surface on the server. Then, remove the
ServeRAID SAS controller from the package.
2. Turn the new ServeRAID SAS controller so that the keys on the bottom edge
align correctly with the connector.
3. Firmly press the ServeRAID SAS controller straight down into the connector by
applying pressure on both ends of the controller simultaneously. The retaining
clips snap into the locked position when the controller is firmly seated in the
connector.
Note: If there is a gap between the controller and the retaining clips, the
controller has not been correctly installed. In this case, open the retaining clips
and remove the controller; then, reinsert the controller.
4. If you are installing a ServeRAID-8k SAS Controller, complete the following
steps:
a. Remove the battery from the ServeRAID-8k SAS controller package.
b. Slide the battery mounting tabs into the battery mounting clips on the server
wall next to the connector.
Chapter 4. Removing and replacing server components 71