5. Push the tape-drive assembly into the bays, gently pulling the cables farther
into the server as you do so, until the tape-drive assembly stops.
6. Push the tray handle to the closed (locked) position.
7. Connect the cable connectors to the following system-board connectors (see
“System-board internal cable connectors” on page 11 for the location of the
connectors):
v Signal connector: SATA tape drive signal connector, J102
v Power connector: tape-drive power connector, J100
The following illustration shows the routing of the SATA tape drive signal cable.
Important: Make sure that the cables avoid any fan connectors.
1 SATA tape cable connector
2 SATA tape cable
8. Install the fan-bracket assembly.
9. Install the cover (see “Installing the cover” on page 57).
10. Slide the server into the rack.
80 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual