Miscellaneouserrormessages
SymptomFRU/Action
ChangingdisplaycolorsDisplay/Monitor
Computerwillnotturnoff.See“Harddiskdriveboot
error”onpage17.
1.Powerswitch
2.Systemboard
3.Risercard,ifinstalled.
ComputerwillnotRPLfromserver
1.EnsurethatNetworkissetastherstdeviceoritis
afterCD/DVDinthestartupsequence.
2.EnsurethatthenetworkadapterisenabledforRPL.
3.Networkadapter(Advisethenetworkadministrator
ofnewMACaddress)
ComputerwillnotperformaWakeOnLAN®(ifapplicable)1.Checkthepowersupplyandsignalcableconnections
tothenetworkadapter.
2.Ensurethattheoperatingsystemsettingsaresetto
enableWakeonLAN.
3.EnsurethattheWakeOnLANfeatureisenabledin
Setup/Conguration(see“StartingtheSetupUtility
program”onpage83.)
4.Ensurethatthenetworkadministratorisusingthe
correctMACaddress.
5.EnsurethatnointerruptorI/Oaddressconicts.
6.Checkthenetworkadapter.
Deadcomputer.See“Harddiskdrivebooterror”onpage
17.
1.Powersupply
2.Systemboard
Diskettedrivein-uselightremainsonordoesnotlight
whendriveisactive.
1.Diskettedrive
2.Systemboard
3.Diskettedrivecable
Blankscreenexceptforashingcursor.
1.Systemboard
2.Primaryharddiskdrive
3.Harddiskdrivecable
IncorrectmemorysizeduringPOST
1.Runthememorytests.
2.Checkthememorymodules.
3.Checkthesystemboard.
"InsertaDiskette"iconappearswithaknown-good
diagnosticsdisketteintherst3.5-inchdiskettedrive.
1.Systemboard
2.Diskettedrivecable
3.Networkadapter
Intensityorcolorvariesfromlefttorightofcharacters
andcolorbars
1.Display
2.Videoadapter(ifpresent)
3.Systemboard
Nopowerorfannotrunning
See“Harddiskdrivebooterror”onpage17.
Non-systemdiskordiskerror-typemessagewitha
known-gooddiagnosticdiskette.
1.Diskettedrive
2.Systemboard
3.Diskettedrivecable