14
1.3 FEATURES AND SPECIFICATIONS
The following information is a summary of the features and specifications of the server.
Technical parameters
Processor
Support 2 UPI links @10.4GT/s and future 11.2GT/s UPI
Memory
Number of slots: 24 DIMMs or 16 DIMMs
hard disk
Front : Up to 12x 3.5-inch Hot Swap SATA/SAS/NVMe HDDs
Rear : 2x 3.5-inch Hot Swap SATA/SAS HDDs
Display
Integrated graphics chip, 16MB
CD-ROM
Supports USB DVDRW drive
Network One dedicate management chip
Keyboard
Mouse
Expansion slots
Supports up to 6 PCIe slots
Device
connectors
VGA x 2 (1 front, 1 rear)
USB3.0 x 3 (2 rear, 1 internal)
USB2.0 x 2 (front)
RJ45 x 1 (Management NIC),
Equipped with automatic energy saving and noise reduction technologies
Compatible with
Windows Server 2008 SP2 (x86) ), Windows Server 2008 R2 with SP1 (including Hyper
Windows Server® 2012 (including Hyper-
V), Windows Server 2012 R2, SUSE LINUX Enterprise Server 11 SP3,
SUSE LINUX Enterprise Server 12, SUSE LINUX Enterprise Server 10 SP2, SUSE LINUX Enterprise Server 11
SP3, RedHat RHEL 6.5, CentOS 5.4 32bit, CentOS 6.3 64bit, Citrix XenServer 6.2
Supported Altitude* (unpressurized): 0-10000ft (0-3050m)
Altitude
A2: Operating temperature de-rated 1°C per 300m (1000ft) to 3050m (10000ft)
above sea level, No A3/A4 support
temperature
(operating)
System support ASHARE A2, and A3, A4 with limitation
No specific humidity definition for A2-A4
Design by project, but if system follow ASHRAE standard, should follow below requirements
Maximum rate of change(℃/hr) should ≤ 20
Humidity transition rate should ≤10%/hr.
A2: 10℃ to 35℃.
Humidity: 8%~80% RH, Non-condensing.
A3: 5℃ to 40℃.
Humidity: 8%~85% RH, Non-condensing.
A4: 5℃ to 45℃.
Humidity: 8%~90% RH, Non-condensing.
Supported Altitude* (unpressurized): 0-10000ft (0-3050m)