Figure 9. System-board switches
1  SW5 2  SW13
SW5 switch block
Table 15.  SW5 switch block definition
Switch 
number
Switch name
Usage description
On Off
1 Force BMC reset
Forces hot reset BMC chip Normal (default)
2 Force BMC CPU reset Forces warm XCC and CPU rest
Normal (default)
3
ME security override Enables ME low security mode Normal (default)
4 Password clear
Forces reset uEFI password Normal (default)
5
Low security Enables XCC low security mode Normal (default)
6
ME recovery Forces ME into recovery mode Normal (default)
7
BMC force update
Forces XCC boot
Normal (default)
8
FPGA power permission 
override
Ignores Power Permission and allows 
system to power on
Normal (default)
30 ThinkSystem SD530 V3 System Configuration Guide