EasyManuals Logo

Lenze 12 Series User Manual

Lenze 12 Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Commissioning and operation
Before switching on
6
19
BA 12.0028−EN 6.0
6 Commissioning and operation
Stop!
The drive may only be commissioned by skilled personnel!
6.1 Before switching on
Check:
ƒ Does the drive appear undamaged?
ƒ Is the mechanical fixing o.k.?
ƒ Has the electrical connection been carried out properly?
ƒ Are all rotating parts and surfaces that may become hot protected against contact?
ƒ If the oil level of the drive has been increased due to storage purposes (see
chapter 4.1), it must be reduced again to the height permissible for the intended
mounting position.
ƒ For gearboxes with breathing:
Has the transport locking device been removed?
6.2 During operation
During operation, check the drive periodically and take special care of:
ƒ Deviations from normal operation such as
abnormal noises, stronger vibrations, or increased temperatures
leakages,
loose fixing elements,
the condition of the electrical cables.
ƒ If any interference should occur, you have to stop the drive and go through the steps
for troubleshooting and fault elimination (chapter 8). If the interference cannot be
eliminated, please contact the Lenze Service.