105
Code Name Parameter
(Factory settings are printed in bold)
Acceptance see
page
Your
settings
C086* Motor frame
size
-0- Size 71, self-ventilated
-1- Size 80, self-ventilated
-2- Size 90, self-ventilated
-3- Size 100, self-ventilated
-4- Size 112, self-ventilated
-5- Size 132, self-ventilated
-6- Size 160, self-ventilated
-7- Size 180, self-ventilated
-8- Size 200, self-ventilated
-9- Size 225, self-ventilated
-10- Size 250, self-ventilated
-100- Size 71, forced-ventilated
-101- Size 80, forced-ventilated
-102- Size 90, forced-ventilated
-103- Size 100, forced-ventilated
-104- Size 112, forced-ventilated
-105- Size 132, forced-ventilated
-106- Size 160, forced-ventilated
-107- Size 180, forced-ventilated
-108- Size 200, forced-ventilated
-109- Size 225, forced-ventilated
-110- Size 250, forced-ventilated
[SH + PRG] 98
C088* Rated motor
current
0.5 I
maxcontroller
0.15...1.0 I
maxcontroller
(in steps of 0.1A to 100A
in steps of 1A as of 100A)
[SH + PRG] 98
C092* Pole pair
number (only
for LECOM)
2 1...6 [SH + PRG] 110
C094* User password 000 000...999
000 = no password request
under C000
SH + PRG 99
C098 Language -0- German
-1- English
-2- French
SH + PRG 99
C099* Software
version
-0- 86 6.4 100
C100 Preselection:
Additional
acceleration
and
deceleration
time (main set-
value)
-1- Pair of ramp times 1
-2- Pair of ramp times 2
... ...
-15- Pair of ramp times 15
SH + PRG 81
C101 Acceleration
time for C100
2.5s 0.0...990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 from 100 to 990 s)
ON-LINE 81
C103 Deceleration
time for C100
2.5s 0.0... 990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 from 100 to 990 s)
ON-LINE 81
C105 Deceleration
time for quick
stop
5.0s 0.0...990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 s from 100 to 990 s)
ON-LINE 58
C107 Holding time
for DC
injection
braking
999s 0.0...999s
999s = Holding time infinite
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 999s)
ON-LINE 79