53
Parameter setting
1 Keypad
Plain text display
PRG
SH STP
RDY
IMP
LENZE 8600
UMRICHTER
max
I
Operating keys
Display of status:
Ready for operation (LED green)
I
max
-limit reached (LED red)
Pulse inhibit (LED yellow), released
by:
Controller inhibit
Fault indication (TRIP)
Undervoltage/overvoltage
1.1 Key functions
Key Function
PRG Change between code and parameter level
SH + PRG * Accept change
Increase displayed number
SH +
Increase displayed number fast (scroll up)
Reduce displayed number
SH +
Reduce displayed number fast (scroll down)
STP Inhibit controller
SH + STP * Enable controller
* First press the SH key and then in addition the PRG or the STP key.
1.2 Plain text display
Position of the arrow marks the activated operating level
(code/parameter level)
Code Parameter Unit
C050 0 . 0 H z Example
Out put f r equency
Explaining text for each code and parameter