60
3.2 Configuration
Using code C005 you can determine the internal control structure
and the use of the set-value and feedback inputs. The following
configurations are possible:
Open-loop speed control:
Code Parameter Meaning Acceptance
Set-value 1 Set-value 2 Actual value
C005 -0- Terminals 7/8, unipolar or
LECOM (bipolar) or
keypad (bipolar)
not active not active [SH + PRG]
-1- Terminals 7/8(bipolar) or
LECOM (bipolar) or
keypad (bipolar)
Terminals 1/2
(bipolar)
not active
-2- Input X5
Digital frequency (2-track)
Terminals 1/2
(bipolar)
not active
Closed-loop control:
Code Parameter Meaning Acceptance
Set-value 1 Set-value 2 Actual value
C005 -11- Terminals 7/8 (bipolar) or
LECOM (bipolar) or
keypad (bipolar)
Terminals 1/2
(bipolar)
Terminals 3/4 analog
feedback (e.g. DC
tacho)
[SH + PRG]
-13- Terminals 7/8 (bipolar) or
LECOM (bipolar) or
keypad (bipolar)
Terminals 1/2
(bipolar)
Input X5
Digital frequency (2-
track)
-14-* Input X8
Digital frequency
Terminals 1/2
(bipolar)
Input X5
Digital frequency (2-
track)
-15-* Input X5
Digital frequency (2-track)
Terminals 1/2
(bipolar)
Input X8
Pulse encoder (2-track)
* According to the configuration selected, set-value 1 or the feedback can
be output via the digital frequency output X9.