67
Code Name Parameter Accept-
ance
see
page
C061
Utilization I x t xxxx Setting range: 0.0...+100.0%
Step: 0.1%
The indicated value is determined by
the current-time integral I x t of the
controller current. When reaching
100% the I x t monitoring sets
overload trip
read only
C067
Fault diagnosis xxx see under "Service" 74
C068
(L)
Operating state see under "Service" read only 59
C069
(L)
Controller state see under "Service" read only 59
C070
V
pn
(gain of
speed
controller)
30
Setting range: 0...500
Step: 1
ON-LINE 49
C071*
T
n
(Integral action
time of speed
controller)
10
9999
Setting range: 2.5...100 ms
Step: 0.5 ms
Deactivate integral component
ON-LINE 49
C072*
k
d
(differential
amplification of
speed
controller)
0
Setting range: 0...5
Step: 0.1
ON-LINE 49
C079*
V
p
(V
z
-controller)
1000
Setting range: 0...9000
Step: 1
ON-LINE 53
C080*
T
n
(V
z
-controller)
1.0 s
Setting range: 0.01...150 ON-LINE 53
C081*
Rated motor
power
xxx.x Setting range: 0.1...650 kW
Step: 0.1 kW
47
C087
Rated motor
speed
xxxx Setting range: 300...6000 rpm
Step: 1 rpm
C088
Rated motor
current
xxx Setting range: 0.1A...max. controller
current
Step: 0.01 A
C089
Rated motor
frequency
xxx.x Setting range: 10.0...300.0 Hz
Step: 0.1 Hz
C091
cos
ϕ
Motor
x.xx Setting range: 0.50...0.99
Step: 0.01
C093*
Controller
identification
xx read only
C094*
Pass word
0
enter any password (0...999)
no password defined
SH+PRG 42
C098
Language -0-
-1-
-2-
German
English
French
Note:
The setting will not be overwritten
when loading the factory setting!
C099*
Software
version
92_5.x Number to identify the software
version
read only
C105
Quick stop
deceleration
time T
QSP
0.01
Setting range: 0.00...990 s
Step: 0.01 s from 0.00...1 s
0.1 s from 1...10 s
1 s from 10...100 s
10 s from 100...990 s
ON-LINE 48