Parameter setting
Parameter setting using the keypad
11
l
EDKVF9333 EN 1.0
2.2.6 Password protec tion
YoucanrestrictthecodeaccessviathekeypadusingthepasswordprotectioninC0094.
Reading C0094 using the keypad:
C0094 = 0: passwor d protection is not activated.
C0094 = 9999: passwor d protection is activated.
Activate p assword protec tion:
Enter four-digit number in C0094.
–ConfirmusingSH+PRG.
Deactivate password protec tion:
Enter four-digit number again.
All other inputs are refused.
Effect
Working with the keypad:
The codes of the USER menu can still be read and changed.
All other codes are no longer displayed.
Working with the fieldbus:
It is possible to extend the protection under C0096/1 (AIF) and C0096/2 (CAN) when
working with a fieldbus.
Selection under C0096/X
C0096/X = 0: No access protection
C0096/X = 1: R ead protection
C0096/X = 2: Write protection
C0096/X = 3: R ead/write protection
2.3 Display fun ctions
Actual v alue display
You can read different actual values using the following codes:
Code Meaning
C0051 Absolute actual speed [rpm]
C0052 Absolute motor voltage [V]
C0053 Absolut e DC bus voltage [V]
C0054 Absolute motor current [A]
C0060 Rotor position [Inc/rev]
C0061 Heatsink temperature [°C]
C0063 Absolute motor temperature [°C]
Display only with connected KTY (PTC) via X7 or X8
C0064 Controller load [%]
Identification
You can read the software version of the controller under C0099.
UnderC0093youcanreadthecontrollertype.