Troubleshootin g and fault elimination
Troubleshooting
2
L
EDKVF9333 EN 1.0
Display via the LECOM status word C0150
Bit Meaning
0 FREE 0 freely combinable
1 IMP (pulse inhibit)
0 = Pulses enabled for power stage
1 = Pulses inhibited for power stage
2 FREE 2 freely combinable
3 FREE 3 freely combinable
4 FREE 4 freely combinable
5 FREE 5 freely combinable
6 f
d
= 0 (actual speed value = 0) 0=[n 0]
1=[n=0]
7 RSP (controller inhibit) 0 = No controller inhibit
1 = Controller inhibit
8-11 Controller status
hex bin
0 0000 Unit initialisation
1 0001 Switch-on inhibit
3 0011 Operation inhibited (controller inhibit)
6 0110 Operation enabled
7 0111 Message active
8 1000 Active fault
9 1001 Power off
A 1010 Fail-QS P
12 Warning 0=Nowarning
1=Warning
13 Meldung 0 = No message
1 = Message
14 FREE 14 freely combinable
15 FREE 15 freely combinable