Networking
Networking with E82ZAFCC system bus function module (CAN)
10
Function library
10.19
10.19.1
L
10.19-2
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0354*
v
Selective system
bus address
0 {1} 513 Only for the E82ZAFCC system bus
function module on the FIF interface.
Individual addressing of system bus
process data objects
^
10.19-1
1 CAN-IN1 (sync) 129
Effective with sync control (C0360 = 1)
2 CAN-OUT1 (sync) 1
y
3 CAN-IN2 257
4 CAN-OUT2 258
5 CAN-IN1 (time) 385
Effective with event and time control
C
6 CAN-OUT1 (time) 386
(C0360 = 0)
C0355*
v
System bus
identifier
0 {1} 2047 Only for the E82ZAFCC system bus
function module on the FIF interface.
Only display
^
10.19-1
1 CAN-IN1
Identifier of CAN1 with sync control (C0360
2 CAN-OUT1
y
=1)
3 CAN-IN2
4 CAN-OUT2
5 CAN-IN1
Identifier of CAN1 with event or time
C
6 CAN-OUT1
control (C0360 = 0)
C0356*
v
System bus time
settings
Only for the E82ZAFCC system bus function
module on the FIF interface.
^
10.19-1
1 Boot up 3000
0 {1 msec} 65000
Required for CAN network without master
2 Cycle time
CAN-OUT2
0
{
}
0 = event-controlled process data transfer
> 0 = cyclic process data transfer
3 Cycle time
CAN-OUT1
0 0 and C0360 = 0: event-controlled process
data transfer
> 0 and C0360 = 1: cyclic process data
transf er
4 CAN delay 20 Waiting t ime until cyclic sending aft er
boot-up
C0357*
v
System bus
monitoring times
Only for the E82ZAFCC system bus function
module on the FIF interface.
^
10.19-1
1 CAN-IN1 (sync) 0
0
= monitoring not
{1 msec} 65000
active, if C0360 = 1
TRIP CE1 a t communication abort
2 CAN-IN2 0
g
active
TRIP CE2 a t communication abort
3 CAN-IN1 (time) 0 active, if C0360 = 0
TRIP CE3 a t communication abort
C0358*
v
Reset node 0
0 Without function
Only for the E82ZAFCC system bus
f
u
n
c
t
i
o
n
m
o
d
u
l
e
o
n
t
h
e
F
I
F
i
n
t
e
r
f
a
c
e
^
1
0
1
9
-
1
v
1 System bus reset
f
unc
t
i
on mo
d
u
l
eon
t
h
e
F
I
F
i
n
t
er
f
ace.
Syst em bus reset node set-up
1
0
.
1
9
-
1
C0359* System bus status
0 Operational
Only for the E82ZAFCC system bus ^
v
y
1 Pre-operational
y
y
function module on the FIF interface.
O
n
l
y
d
i
s
p
l
a
y
10.19-1
2 Warning
Only display
3 Bus off
C0360* Control of process
C
1
0 Event or time control
Only for the E82ZAFCC system bus function
v
p
data channel CAN1
1 Sync control
y
y
module on the FIF interface.