Code table
10
Function library
10.20
L
10.20-35
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0417*
v
Free configuration
of controller status
messages (1)
Output of digital signals to bus The assignment is mapped to the
• Controller status word 1 (C0150)
• AIF status word (AIF-STAT)
• FIF output word 1 (FIF-OUT.W1)
• Output word 1 in CAN object 1
(CAN-OUT1.W1)
^
10.13-12
1 Bit 0 1 Active parameter set
PAR-B0 active (DCTRL1-PAR-B0)
à Fixed assignment to AIF when
operating with communication
2 Bit 1
2 Pulse inhibit active (DCTRL1-IMP)
modules INTERBUS 211x,
à
-
or
-
21
2. M
ifi
i
n
r
n
ll
w
!
3 Bit 2 3 I
max
limit reached (MCTRL1-IMAX)
(C0014 = -5-: Torque setpoint re ached)
.
If you use function modules system bus
(CAN), INTERBUS, PROFIBUS-DP to FIF, all
4 Bit 3 4 Frequenc y setpoint reached
(DCTRL1-RFG1=NOUT)
bits are freely configurable.
5 Bit 4 5 Ramp function generator 1: Input = output
(NSET1-RFG1-I=O)
6 Bit 5 6 V alue below frequency threshold Q
min
(f < C0017)
(PCTRL1-QMIN)
7 Bit 6
7 Output frequency = 0 (DCTRL1-NOUT=0)
à
8 Bit 7
8 Controller inhibit active (DCTRL1-CINH)
à
9 Bit 8 9
à
11|10|9|8
0000
0001
Controller status
Controller initialization
Mains voltage off (at external supply of the
control section ofthe drive controller)
10 Bit 9 10
à
0010
0011
Switch-on inhibit
Operation inhibited
11 Bit 10 11
à
0100
0101
Flying restart circuit active
DC-injection brake active
12 Bit 11 12
à
0111
1000
Message active
Active error
13 Bit 12
13 Collective message:
(DCTRL1-OH-PTC-LP1-FAN1-WARN)
à
14 Bit 13
14 DC-bus overvoltage (DCTRL1-OV)
à
15 Bit 14 15 CCW rotation (DCTRL1-CCW)
16 Bit 15 16 Ready for operation (DCTRL1-RDY)
Digital signals p os sible for C0417 s ee C0415
C0418*
v
Free configuration
of controller status
messages (2)
Output of digital signals to bus
All bits can be freely configured
The assignment is mapped to the
• Controller status word 2 (C0151)
^
10.13-12
1 Bit 0 255 Not assigned (FIXED-FREE)
• FIF output word 2 (FIF-OUT.W2)
... ... ...
• Output word 1 in the CAN object 2
16 Bit 15 255 Not assigned (FIXED-FREE)
(C
N-OUT2.W1)
Digital signals p os sible for C0418 s ee C0415
C0419
v
Free configuration
of analog outputs
Analog signal output to terminal
^ 10.12-4
1 X3/62 (AOUT1-IN) 0 Output frequency (MCTRL1-NOUT+SLIP) The selection made under C0111 is
copied to C0419/1. A chan ge of C0419/1
sets C0111 = 255!
2(A) X3/63 (AOUT2-IN) 2 Apparent motor current (MCTRL1-IMOT)
3(A) X3/A4 (DFOUT1-IN) 3 DC-bus voltage (MCTRL1-DCVOLT) Frequency output: 50 Hz ... 10 kHz