Code table
10
Function library
10.20
L
10.20-25
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0356*
v
System bus time
settings
Only for the E82ZAFCC system bus function
module on the FIF interface.
^ 10.19-1
1 Boot up 3000
0 {1 msec} 65000
Required for CAN network without master
2 Cycle time
CAN-OUT2
0
0 = event-controlled process data transfer
> 0 = cyclic process data transfer
3 Cycle time
CAN-OUT1
0 0 and C0360 = 0: event-controlled process
data transfer
> 0 and C0360 = 1: cyclic process data
transf er
4 CAN delay 20 Waiting t ime until cyclic sending aft er
boot-up
C0357*
v
System bus
monitoring times
Only for the E82ZAFCC system bus function
module on the FIF interface.
^ 10.19-1
1 CAN-IN1 (sync) 0
0
= monitoring not
{1 msec} 65000
active, if C0360 = 1
TRIP CE1 a t communication abort
2 CAN-IN2 0
active
TRIP CE2 a t communication abort
3 CAN-IN1 (time) 0 active, if C0360 = 0
TRIP CE3 a t communication abort
C0358*
Reset node 0
0 Without function
• Only for the E82ZAFCC system bus
^ 10.19-1
1 System bus reset
unc
on mo
u
eon
e
n
er
ace.
• Syst em bus reset node set-up
C0359* System bus status
0 Operational
• Only for the E82ZAFCC system bus ^ 10.19-1
v
1 Pre-operational
function module on the FIF interface.
2 Warning
• Only display
3 Bus off
C0360* Control of process
1
0 Event or time control
Only for the E82ZAFCC system bus function
v
data channel CAN1
1 Sync control
module on the FIF interface.
C0370*
v
Activate remote
parameter setting
via system bus
(CAN)
0 Deactivated • Only for the E82ZAFCC system bus
function module on the FIF interface.
• Can only be read when using all other
bus function modules on FIF.
^ 9.3-10
^ 9.4-9
1 ... 63 Activates corresponding CAN address 1 = CAN address 1
63 = CAN address 63
255 No system bus (CAN) Only display
C0372* Function module
0 No function module
Only display
identification
1 Standard I/O or AS-i
2 System bus (CAN)
6 Other function module on FIF
e.g. application I/O, INTERBUS, ...
10 No valid recognition
C0395* LONGWORD
process input data
Bit 0..15 Controller word (mapping to C0135)
For bus operation only
• Sending of control word and main
Bit 16...31 Setpoint 1 (NSET1-N1) (mapping to C0046)
setpoint in a telegram to controller
• In keypad: display only (hexadecimal)
C0396* LONGWORD
process output data
Bit 0...15 Controller status word 1
(mapping of C0150)
For bus operation only
• Reading of status word and output
Bit 16...31 Output frequenc y (MCTRL1-NOUT)
(mapping of C0050)
frequency in a telegram from controller
• In keypad: display only (hexadecimal)
C0409
Configuration relay
Output of digital signals to relay K2
• Relay output K 2 only with 8200 vector
^ 10.13-6
v
output K2
255 255 Not assigned (FIXED-FREE)
15 ... 90
W
• F
r
r
i
nwi
h
li
i
n-I
nl
Digital signals p os sible for C0409 s ee C0415
-
active as of version E82ZAFA...XXVx2x