Transmit parameter sets
EDK82ZBC DE/EN/FR 3.1
58
Parameter ändern u speichern----(DUMMYSEITEVOR)---
Copying parameter sets from the keypad to the standard device
Step Key
sequence
Result Action
1. Connect keypad to standard device 2
xx.xx Hz
The function is active. The first code is shown in
the user menu (C0517/1, Lenze setting: C0050 =
Output frequency).
2. Disable controller
The drive coasts to a stop.
3.
Select C0002 in the user menu
4.
0002 C0002 is selected
5.
6.
Select the correct copying function The settings stored in the standard device or in the
function module are overwritten.
z Copying all the available parameter sets (PAR1 ... PAR4 and, if necessary, FPAR1) to the standard device:
– Standard device with function
module Application I/O, AS
interface,
INTERBUS, PROFIBUS, LECOM-B,
DeviceNet, or CANopen
70 PAR1 ... PAR4 and FPAR1 are copied:
Ö ”70” is set
– Standard device with all other
function modules
10 PAR1 ... PAR4 are copied:
Ö ”10” is set
z Copying only the module-specific parameter s et FPAR1 to the function module:
– Only possible for standard
devices with function module
INTERBUS,
PROFIBUS, LECOM-B, DeviceNet,
or CANopen
40 FPAR1 is copied:
Ö ”40” is set