Operation
Transmit parameter sets
6
EDK82ZBC DE/EN/FR 3.1
59
Parameter ändern u speichern----(DUMMYSEITEVOR)---
ActionResultKey
sequence
Step
z Copying individual parameter sets (PARx and, if necessary, FPAR1) to the standard device:
– Standard device with function
module Application I/O,
INTERBUS,
PROFIBUS, LECOM-B, DeviceNet,
or CANopen
71 PAR1 and FPAR1 are copied:
Ö ”71” is set
72 PAR2 and FPAR1 are copied:
Ö ”72” is set
73 PAR3 and FPAR1 are copied:
Ö ”73” are set
74 PAR4 and FPAR1 are copied:
Ö ”74” is set
– Standard device with all other
function modules
11
PAR1 is copied: Ö ”11” is set
12
PAR2 is copied: Ö ”12” is set
13
PAR3 is copied: Ö ”13” is set
14
PAR4 is copied: Ö ”14” is set
7. Start copying
STOrE
or
LOAd
The selected parameter sets are copied to the
standard device or to the function module.
When STOrE or LOAd stops being displayed, copying
has been completed.
8. Enable controller
The drive starts running again.