EasyManua.ls Logo

Lenze E94AYCET

Lenze E94AYCET
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06 107
14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13534
C13535
Parameter | Name:
C13534 | Mapping entries TPDO-4
Data type: UNSIGNED_64
Index: 11041 = 0x2B21
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the TPDO channel 4.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C13534/1 0 1. Mapping entry TPDO-4 (I-1A03.01)
... ... ...
C13534/32 0 32. Mapping entry TPDO-4 (I-1A03.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13535 | Mapping entries TPDO-5
Data type: UNSIGNED_64
Index: 11040 = 0x2B20
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the TPDO channel 5.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C13535/1 0 1. Mapping entry TPDO-5 (I-1A04.01)
... ... ...
C13535/32 0 32. Mapping entry TPDO-5 (I-1A04.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT

Table of Contents

Related product manuals