6 Commissioning
6.5 Synchronisation with "Distributed clocks" (DC)
38
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.5.2 DC configuration in the Servo Drive 9400 (slave)
In order to be able to use the DC synchronisation in the Servo Drive 9400, go to the Settings tab in
the Sync source selection field and select the sync source (C01120
):
Selection 4: Module in slot MXI1 of the Servo Drive 9400
Selection 5: Module in slot MXI2 of the Servo Drive 9400
Note!
The settings of the parameters sync cycle time (C01121), sync phase position (C01122),
sync tolerance (C01123) and sync PLL increment (C01124) common for the Lenze system
bus (CAN) cannot be made for EtherCAT. These values are automatically calculated by
the EtherCAT communication module and set internally in the inverter.