Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06 111
14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13850
C13851
C13852
Parameter | Name:
C13850 | All words to master
Data type: UNSIGNED_16
Index: 10725 = 0x29E5
Display of the process data words (subcodes 1 ... 32) which are transferred from the communication module to the
master.
Only those which are configured are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13850/1
...
C13850/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724 = 0x29E4
Display of the process data words (subcodes 1 ... 32) which are transferred from the master to the communication
module.
Only those which are configured are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13851/1
...
C13851/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13852 | All words to standard device
Data type: UNSIGNED_16
Index: 10723 = 0x29E3
Display of the process data words (subcodes 1 ... 32) which are transferred from the communication module to the
standard device.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13852/1
...
C13852/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT