14 Parameter reference
14.3 Parameters of the communication module for slot MXI2
122
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14239
C14240
Parameter | Name:
C14239 | Mapping entries RPDO-9
Data type: UNSIGNED_64
Index: 10336 = 0x2860
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 9.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C14239/1 0 1. Mapping entry RPDO-9 (I-1608.01)
... ... ...
C14239/32 0 32. Mapping entry RPDO-9 (I-1608.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14240 | Mapping entries RPDO-10
Data type: UNSIGNED_64
Index: 10335 = 0x285F
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 10.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C14240/1 0 1. Mapping entry RPDO-10 (I-1609.01)
... ... ...
C14240/32 0 32. Mapping entry RPDO-10 (I-1609.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT