Questions and Answers

  • K
    Karina HamptonSep 1, 2025
    How to fix communication error on Lenze ESMD113L4TXA?
    • B
      boydemilySep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • E
    Elizabeth WalkerSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze Inverter?
    • S
      Stacey VangSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • L
    Luke DorseyAug 30, 2025
    What causes motor overload on Lenze ESMD113L4TXA Inverter?
    • J
      Jeffrey GoodmanAug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.
  • C
    Carrie SalasSep 13, 2025
    What does it mean when Lenze DC Drives reach the current limit?
    • A
      Amy MartinSep 13, 2025
      Reaching the current limit in Lenze DC Drives indicates a controllable overload, which is managed automatically.
  • A
    Alexander RhodesSep 13, 2025
    What causes overvoltage on DC bus in Lenze DC Drives and how to fix it?
    • C
      carmen84Sep 13, 2025
      Overvoltage on the DC bus in Lenze DC Drives can be caused by several factors. It may be due to mains voltage being too high, so you should check the mains voltage. Another cause can be an excessively short deceleration time or the motor operating in generator mode; in this case, increase the deceleration time or use a dynamic braking option. Finally, earth leakage on the motor side can also cause this issue, so check the motor and motor cable, separating the motor from the controller.
  • A
    Ashley OrrSep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • R
      Ronald Williams Jr.Sep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • L
    Lisa ThomasSep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • T
      Taylor RobertsSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • B
    Brady GonzalezAug 27, 2025
    How to resolve dynamic braking fault in Lenze DC Drives?
    • J
      John EsparzaAug 27, 2025
      A dynamic braking fault in Lenze DC Drives typically means that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • J
    Joseph JimenezAug 26, 2025
    What to do if Lenze DC Drives show undervoltage on DC bus?
    • A
      antoniojohnsonAug 26, 2025
      If Lenze DC Drives show undervoltage on the DC bus, it could be because the mains voltage is too low. Check the mains voltage.
  • K
    Kristin BrayAug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • M
      Melanie HallAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.

Summary

Safety Information

General Safety and Application Guidelines

Covers general hazards, intended use, and compliance with machinery and EMC directives.

Installation and Electrical Connection Safety

Details safe handling, electrostatic discharge prevention, and electrical connection regulations.

Operational Safety and Pictographs

Ensures safe operation, explains safety symbols, and warns about capacitor charge.

UL Compliance and Specific Hazard Warnings

Addresses UL requirements and provides critical warnings for electrical shock and fire risks.

Commissioning

Troubleshooting and Fault Elimination

Error Code Fault Resolution

Details causes and remedies for specific error codes related to EPM, digital inputs, braking, communication, and keypad faults.

Overload, Earth Fault, and Overtemperature Issues

Addresses troubleshooting for short-circuits, overloads, earth faults, and controller overtemperature conditions.