  • D
    davidhannahSep 8, 2025
    Why is the current consumption of my Lenze EVF8214-EV020 motor too high?
    • O
      oliviaoliverSep 8, 2025
      High current consumption in the motor can be attributed to a few settings. The setting of C016 might be too high, or the setting of C015 might be too low. Additionally, C088 and C091 might not be adapted to the motor data.
  • C
    Cynthia HowardSep 9, 2025
    What causes grounded motor phase in Lenze EVF8214-EV020?
    • W
      William CrossSep 10, 2025
      A grounded motor phase can be caused by a grounded motor phase. Check the motor and cable. Also, excessive capacitive charging current of the motor cable can lead to a grounded motor phase; use a motor cable which is shorter or of lower capacitance.
  • A
    Anthony BarrySep 12, 2025
    Why is my Lenze EVF8214-EV020 motor not rotating smoothly?
    • R
      Regina BellSep 12, 2025
      If the motor isn't rotating smoothly, it could be due to a defective motor cable. The maximum current C022 and C023 might also be set too low. Another possibility is that the motor is underexcited or overexcited; check the parameter setting.
  • D
    donna50Sep 13, 2025
    What to do if mains voltage is too high in Lenze EVF8214-EV020 DC Drives?
    • S
      Steven DavisSep 13, 2025
      If the mains voltage is too high, check the voltage supply. It could also be due to feedback operation during braking. Increase deceleration times. For operation with brake choppers, check the selection and connection of the brake resistor and increase the deceleration times. Another cause may be Earth leakage on the motor side, check motor cable and motor for earth fault (disconnect motor from inverter).
  • J
    James DavisSep 15, 2025
    What causes faulty parameter transfer via the operating module in Lenze DC Drives?
    • T
      tsnyderSep 15, 2025
      If PAR1 and PAR2 are defective, it can cause a faulty parameter transfer. It is absolutely necessary to repeat the data transfer or load the factory setting before enabling the controller.
  • S
    Shannon MaxwellSep 18, 2025
    What causes faulty auto-TRIP reset in Lenze DC Drives?
    • C
      Chad MooreSep 18, 2025
      Faulty auto-TRIP reset is caused by more than 8 fault messages in 10 minutes. The solution depends on the fault message.

Summary

2 Safety Information

2.1 General Safety Information

Provides fundamental safety guidelines and precautions for operating the controllers.

Safety and Application Notes for Controllers

Specific safety notes related to controller application and usage.

3 Technical Data

3.2 Rated Data (Operation with 120 % Overload)

Lists electrical and performance specifications for 120% overload operation.

3.3 Rated Data (Operation with 150 % Overload)

Details electrical and performance specifications for 150% overload operation.

4 Installation

4.1 Mechanical Installation

Covers requirements for physically mounting the controllers and ensuring proper ventilation.

4.2 Electrical Installation

Details the procedures and regulations for connecting the drive controller electrically.

5 Commissioning

5.1 Before You Switch On

Critical checks and wiring verification before initial power-up.

5.2 Short Set-up (Factory Setting)

Outlines the initial setup process and key parameters for factory default operation.

5.3 Adapt Machine Data

Explains how to adjust controller parameters to match the connected machine's characteristics.

5.4 Optimisation of the Operating Characteristic of the Drive

Guides users on tuning drive performance for optimal torque, current, and power.

5.5 Operation with the PID Controller

Describes how to use the integrated PID controller for process control applications.

6 During Operation

7 Configuration

8 Troubleshooting and Fault Elimination

8.1 Troubleshooting

Guides users on identifying and diagnosing operational issues and faults.