Function block library
7-165
SHB9300CRV EN 2.0
Signal Source Note
Name Type DIS DIS format CFG List Lenze
NSET-N a C0046 dec [%] C0780 1 50 Provided for main setpoint; other signals are
permissible
NSET-NADD a C0047 dec [%] C0782 1 5650 Provided for additional setpoint; other signals
are permissible
NSET-JOG*1 d C0799/4 bin C0787/1 2 53
Selection and control of overriding ”fixed
s
e
t
p
o
i
n
t
s
f
o
r
t
h
e
m
a
i
n
s
e
t
p
o
i
n
t
NSET-JOG*2 d C0799/5 bin C0787/2 2 1000
S
e
l
e
c
t
i
o
n
a
n
d
c
o
n
t
r
o
l
o
f
o
v
e
r
r
i
d
i
n
g
f
i
x
e
d
setpoints” for the main setpoint
NSET-JOG*4 d C0799/6 bin C0787/3 2 1000
NSET-JOG*8 d C0799/7 bin C0787/4 2 1000
NSET-TI*1 d C0799/8 bin C0788/1 2 1000
Selection and control of alternative fixed
s
e
t
p
o
i
n
t
s
f
o
r
t
h
e
m
a
i
n
s
e
t
p
o
i
n
t
NSET-TI*2 d C0799/9 bin C0788/2 2 1000
S
e
l
e
c
t
i
o
n
a
n
d
c
o
n
t
r
o
l
o
f
a
l
t
e
r
n
a
t
i
v
e
f
i
x
e
d
setpoints” for the main setpoint
NSET-TI*4 d C0799/10 bin C0788/3 2 1000
NSET-TI*8 d C0799/11 bin C0788/4 2 1000
NSET-N-INV d C0799/1 bin C0781 2 10251 Control of the signal inversion for the main
setpoint
NSET-NADD-INV d C0799/2 bin C0783 2 1000 Control of the signal inversion for the
additional setpoint
NSET-RFG-0 d C0799/12 bin C0789 2 1000 The main setpoint integrator is led to zero via
the momentary T
i
times
NSET-RFG-STOP d C0799/13 bin C0790 2 1000 Holding (freezing) of the main setpoint inte-
grator to its momentary value
NSET-CINH-VAL a C0798/1 dec [%] C0784 1 5001 The signal is generated which the main
setpoint integrator is to be accepted when
the controller is inhibited
NSET-SET a C0798/2 dec [%] C0785 1 5000 The signal is generated which the main set-
point integrator is to be accepted when the
NSET-LOAD input is set
NSET-LOAD d C0799/3 bin C0786 2 5001 Control of the two ramp generators in special
situations e.g. QSP
NSET-OUT a - - - - - -
NSET-RFG-I=0 d - - - - - -
Function
l
Main setpoint channel
l
JOG setpoints
l
Setpoint inversion
l
Sramp
7.6.52.1 Main setpoint channel
l
The signals in the main setpoint channel are limited to the range of ±199.99 %.
l
The signal at input NSET-N is led via the function JOG selection.
l
The JOG function has priority over the setpoint input NSET-N. This means a selected JOG
value switches the input to inactive. The following signal conditioning uses the JOG value
instead.
Show/Hide Bookmarks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9323-EK and is the answer not in the manual?

Lenze EVS9323-EK Specifications

General IconGeneral
BrandLenze
ModelEVS9323-EK
CategoryDC Drives
LanguageEnglish

Related product manuals