Appendix
11-18
BA9300SU EN 2.1
Code ImportantPossible settingsLCDCode Important
ChoiceLenze
LCD
C0017
)&2'( 40,1
50 -16000 {1 rpm} 16000
18kHzsin
216kHzsin
Switching threshold n
act.
<n
x
n
act.
< C0017:
activates the comparator output CMP1-OUT
1: Power optimised operation
2: Noise optimiszed operation
C0018
GEIOP
1 0{1} 2Chopper frequency fchop
Noise optimised operation with automatich
changeover to 8 kHz
0 16/8 kHz
18kHzsine
216kHzsine
C0019
7+5(6+ 1$&7
0 0 {1 rpm} 16000 Threshold nact ,ifn
act.
= 0 is recognized.
C0021
6MJPEONP
0.00 0.00 {0.01 %} 20.00 Slip compensation
active only in sensorless control
C0022
,0$; &855(17
* 0 {0.01 A} 2.00 I
r
Imax limit current for 9321 to 9324
Å
depends on C0086
• Change of C0086 resets value to the
assigned factory setting (1.5*Imotor)
• With 9321 to 9324 changeover when
controller is inhibited to I
max
>1.5I
r
possible
[C0025]
)(('%$&. 7<3(
10 0 COMMON
1 no feedback
10 RSx (Resolve r)
interface Stegmann
• 410: AM-512-8V single-turn Sin-Cos
encoder, Stegmann
C0026
1
2
)&2'( OGGRFS
)&2'( OGGRFS
0.00
0.00
-199.99 {0.01 %} 199.99 FCODE (OffsetAIN)
Used for relative analog signals
1: Offset for terminal X6/1,2
2: Offset for terminal X6/3,4
C0027
1
2
)&2'( *$,1
)&2'( *$,1
100.00
100.00
-199.99 {0.01 %} 199.99 FCODE (AIN)
Used for relative analog signals
1: Gain X6/1,2
2: Gain X6/3,4