EasyManua.ls Logo

Lenze EVS9326-EK

Lenze EVS9326-EK
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preface and general information
1-7
SHB9300CRV EN 2.0
Considered basic standards for the test of the noise emission:
Basic standard Test Limit value
EN 55022 7/92 Radio interference housing and mains
Frequency range 0.15 - 1000 MHz
Class B
for use in residential areas and
commercial premises
EN 55011 7/92
(used in addition to the requirements of
IEC 22G)
Radio interference housing and mains
Frequency range 0.15 - 1000 MHz
The emission of noise in industrial premises is not limited in
IEC 22G.
Class A
for use in
industrial premises
IEC 801-2 /91 Electrostatic discharge
on housing and heatsink
Severity 3
6 kV for contact,
8 kVclearance
IEC 1000-4-3 Electromagnetic fields
Frequency range 26 - 1000 MHz
Severity 3
10 V/m
ENV 50140 /93 High-frequency field
Frequency range 80 - 1000 MHz,
80% amplitude-modulated
Severity 3
10 V/m
Fixed frequency
900 MHz with 200 Hz, 100 % modulated
10 V/m
IEC 801-4 /88 Fast transients,
burst on power terminals
Severity 3
2kV/5kHz
Burst on bus and control cables Severity 4
2kV/5kHz
IEC 801-5 Surge test
mains cables
Installation class 3
Hameln, 01 January,1997
(i.V.Funk) (i.V.Lackhove)
Product Manager Project Manager