General informaon
Thermal power limit
The thermal power limit, dened by the heat balance, limits the permissible connuous
gearbox power. It is aected by
the churning losses in the lubricant. These are determined by the mounng posion and
the circumferenal speed of the gears
the load and the speed spectrum.
the ambient condions: temperature, air circulaon, input or dissipaon of heat via shas
and the foundaons.
NOTICE
A thermal check with the Drive Soluon Designer (DSD) or contacng your Lenze
representave is required if
the input speed n
1
> 1500 rpm is fallen below in case of the gearbox raos given in the
following.
the drive speeds menoned in the following will be exceeded as a funcon of the mounng
posion. For a short period of me up to 5 min, 30 % higher speeds are permissible.
the ambient temperature is predominantly above +30 °C.
Gearboxes Rao i
g500-B1500 ... B4300 ≤ 50
Motor Mounng posion M1 Mounng posion M3, M5, M6 Mounng posion M2, M4
m850-S120 4000 rpm 3500 rpm 3000 rpm
m850-S140/S190 3000 rpm 2600 rpm 1500 rpm
Possible ways of extending the applicaon area
Sha sealing ring made of FKM material/Viton (opon)
Reducing the lubricant amount (aer consultaon with Lenze)
Cooling the geared motor by air convecon on the machine/system
Informaon on project planning
General informaon
23

Table of Contents

Other manuals for Lenze G7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze G7 Series and is the answer not in the manual?

Lenze G7 Series Specifications

General IconGeneral
BrandLenze
ModelG7 Series
CategoryEngine
LanguageEnglish

Related product manuals