EasyManua.ls Logo

Lenze HighLine E94AMHE0174

Lenze HighLine E94AMHE0174
206 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring the device modules
Function modules
8
71
EDK94AMH24 DE/EN/FR/ES/IT 1.0
8.2 Function modules
Use these modules in slot ; MXI1 or ;MXI2 MMI MSI.
Digital frequency
E94AYFLF004
Connections
Pos. Description
X9 Input for digital frequency, 9-pole Sub-D plug
X10 Output for digital frequency, 9-pole Sub-D socket
X9 Pin Designation Explanation
1
6
5
9
1 B
TTL input signal from encoder or encoder simulation
2 A
3 A
4 +5 V Regulated voltage supply f or encoder
(pin 8 = sense has to be used)
5 GND -
6 Z
TTL input signal from encoder or encoder simulation
7 Z
8
The function of this lead has to be set in the standard device:
z S
z Lc
z E
z Sense (sensor lead for voltage regulation, Lenze setting)
z Lamp control
z Enable
SUBD09010
9 B TTL input signal from encoder or encoder simulation

Table of Contents