Error code Description Classication Remedy Blocking time [s]
7180 Motor overcurrent Trouble
Check motor load.
Check drive sizing.
Adapt the set error threshold (P353.01).
1
9080 Keypad removed Trouble Connect the keypad again or activate another control source. 0
FF06 Motor overspeed Trouble Adapt the maximum motor speed (P322.00) and the error threshold (P350.01). 1
FF37 Automatic start disabled Trouble Deactivate start command and reset error. 0
FF85 Keypad full control active Warning Press the CTRL key to exit control mode. 0