EasyManua.ls Logo

Lenze I51AE175B - Page 471

Lenze I51AE175B
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Designaon Default seng Category Data type Factor A M
0x2862
(P701.00)
Keypad setpoint increment 1 general U16 1 P -
0x2863
(P705.00)
Keypad language selecon English [1] general U8 1 P -
0x2864
(P703.00)
Keypad status display 0x00000000 general IDX 1 PH -
0x2900:001
(P332.01)
Speed controller sengs: Gain 0.00193 Nm/rpm * MCTRL U32 100000 P -
0x2900:002
(P332.02)
Speed controller sengs: Reset me 80.0 ms * MCTRL U16 10 P -
0x2904 Actual speed lter me 2.0 ms MCTRL U16 10 P -
0x2910:001
(P335.01)
Motor moment of inera 3.70 kg cm² * MCTRL U32 100 P -
0x2910:002
(P335.02)
Load moment of inera 3.70 kg cm² * MCTRL U32 100 P -
0x2910:003 Coupling With backlash [2] MCTRL U8 1 P -
0x2911:001
(P450.01)
Frequency setpoint presets: Preset 1 20.0 Hz general U16 10 P -
0x2911:002
(P450.02)
Frequency setpoint presets: Preset 2 40.0 Hz general U16 10 P -
0x2911:003
(P450.03)
Frequency setpoint presets: Preset 3 Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
general U16 10 P -
0x2911:004
(P450.04)
Frequency setpoint presets: Preset 4 0.0 Hz general U16 10 P -
0x2911:005
(P450.05)
Frequency setpoint presets: Preset 5 0.0 Hz general U16 10 P -
0x2911:006
(P450.06)
Frequency setpoint presets: Preset 6 0.0 Hz general U16 10 P -
0x2911:007
(P450.07)
Frequency setpoint presets: Preset 7 0.0 Hz general U16 10 P -
0x2911:008
(P450.08)
Frequency setpoint presets: Preset 8 0.0 Hz general U16 10 P -
0x2911:009
(P450.09)
Frequency setpoint presets: Preset 9 0.0 Hz general U16 10 P -
0x2911:010
(P450.10)
Frequency setpoint presets: Preset 10 0.0 Hz general U16 10 P -
0x2911:011
(P450.11)
Frequency setpoint presets: Preset 11 0.0 Hz general U16 10 P -
0x2911:012
(P450.12)
Frequency setpoint presets: Preset 12 0.0 Hz general U16 10 P -
0x2911:013
(P450.13)
Frequency setpoint presets: Preset 13 0.0 Hz general U16 10 P -
0x2911:014
(P450.14)
Frequency setpoint presets: Preset 14 0.0 Hz general U16 10 P -
0x2911:015
(P450.15)
Frequency setpoint presets: Preset 15 0.0 Hz general U16 10 P -
0x2912:001
(P452.01)
Torque setpoint presets: Preset 1 100.0 % general I16 10 P -
0x2912:002
(P452.02)
Torque setpoint presets: Preset 2 100.0 % general I16 10 P -
0x2912:003
(P452.03)
Torque setpoint presets: Preset 3 100.0 % general I16 10 P -
0x2912:004
(P452.04)
Torque setpoint presets: Preset 4 100.0 % general I16 10 P -
0x2912:005
(P452.05)
Torque setpoint presets: Preset 5 100.0 % general I16 10 P -
* Default seng depending on the size. Firmware version 05.00.00.00