Address Designaon Default seng Category Data type Factor A M
0x2D66:003
(P721.03)
Mains failure control: Gain V-controller 0.01000 Hz/V general U16 100000 P -
0x2D66:004
(P721.04)
Mains failure control: Reset me V-controller 20 ms general U16 1 P -
0x2D66:005
(P721.05)
Mains failure control: DC voltage setpoint 100 % general U8 1 P -
0x2D66:006
(P721.06)
Mains failure control: Setpoint ramp 20 ms general U16 1 P -
0x2D66:007
(P721.07)
Mains failure control: Clear me 20 ms general U16 1 P -
0x2D66:008
(P721.08)
Mains failure control: Restart threshold 0.0 Hz general U16 10 P -
0x2D66:009
(P721.09)
Mains failure control: Status mains failure control - (Read only) general U8 1 O t
0x2D67:001
(P329.01)
Maximum torque monitoring: Response No response [0] MCTRL U8 1 P -
0x2D67:002
(P329.02)
Maximum torque monitoring: Triggering delay 0.000 s MCTRL U16 1000 P -
0x2D81:001
(P151.01)
Life-diagnosis: Operang me x s (Read only) general U32 1 T -
0x2D81:002
(P151.02)
Life-diagnosis: Power-on me x s (Read only) general U32 1 T -
0x2D81:003
(P151.03)
Life-diagnosis: Control unit operang me x ns (Read only) general U64 1 T -
0x2D81:004
(P151.04)
Life-diagnosis: Main switching cycles - (Read only) general U32 1 - -
0x2D81:005
(P151.05)
Life-diagnosis: Relay switching cycles - (Read only) general U32 1 - -
0x2D81:006
(P151.06)
Life-diagnosis: Short-circuit counter - (Read only) general U16 1 - -
0x2D81:007
(P151.07)
Life-diagnosis: Earth fault counter - (Read only) general U16 1 - -
0x2D81:008
(P151.08)
Life-diagnosis: Clamp acve - (Read only) general U16 1 - -
0x2D81:009
(P151.09)
Life-diagnosis: Fan operang me x s (Read only) general U32 1 T -
0x2D84:001
(P117.01)
Heatsink temperature x.x °C (Read only) general I16 10 O -
0x2D84:002 Heatsink temperature: Warning threshold 80.0 °C * general I16 10 P -
0x2D87
(P105.00)
DC-bus voltage x V (Read only) general U16 1 O t
0x2D88
(P104.00)
Motor current x.x A (Read only) general I16 10 O t
0x2D89
(P106.00)
Motor voltage x VAC (Read only) general U16 1 O t
0x2DA2:001
(P108.01)
Output power: Eecve power x.xxx kW (Read only) general I32 1000 O t
0x2DA2:002
(P108.02)
Output power: Apparent power x.xxx kVA (Read only) general I32 1000 O t
0x2DA3:001
(P109.01)
Output energy: Motor x.xx kWh (Read only) general I32 100 O t
0x2DA3:002
(P109.02)
Output energy: Generator x.xx kWh (Read only) general I32 100 O t
0x2DA4:001
(P110.01)
Diagnoscs of analog input 1: Value in percent x.x % (Read only) general I16 10 O t
0x2DA4:002
(P110.02)
Diagnoscs of analog input 1: Frequency value x.x Hz (Read only) general I16 10 O t
0x2DA4:003
(P110.03)
Diagnoscs of analog input 1: Process controller
value
x.xx PID unit (Read only) general I16 100 O t
* Default seng depending on the size. Firmware version 05.00.00.00
Appendix
Parameter aribute list